B&R Industrial Automation (a Business Unit of ABB) 0ACS100A.90-1
0ACS100A.90-1
Категории:
Технические характеристики
| Natural resonance (installed) | 22 kHz (rated) |
|---|---|
| Sensitivity | 100 mV/g ±10% nominal 80 Hz at 22°C |
| Frequency response | 2 Hz to 10 kHz ±5%0.8 Hz to 15 kHz ±3 dB |
| Isolation | Isolated base |
| Measurement range | ±50 g |
| Cross-sensitivity | <5% |
| Electrical disturbances | Max. 0.1 mg |
| Broadband resolution | 0.2 mg (200 µg) over 1 Hz to 15 kHz |
| Spectral noise | 10 Hz to 10 µg/Hz100 Hz to 4 µg/Hz1 kHz to 3 µg/Hz |
| Current range | 0.5 to 8 mA |
| Напряжение питания | 10 to 12 VDC |
| Settling time | 2 s |
| Output impedance | Max. 200 Ω |
| Housing isolation | >108Ω at 500 V |
| Degree of protection per EN 60529 | IP67 |
| Operation | -55 to 140°C |
| Max. shock resistance | 5000 g |
| Emitted interferences | EN 61000-6-4:2001 |
| Immunity to interference | EN 61000-6-2:1999 |
| Материал | Stainless steel |
| Installation | M8 x 1.25 x 33 mm screw, included in delivery |
| Масса | 170 g |
| Measurement element | PZT piezoelectric crystal (lead zirconate titanate) |
| Measurement execution | Compressed |
| Tightening torque | 8 Nm |
| Connectors | M12 |