| B&R ID code | 0x1CE6 |
|---|
| Status LED | Yes (color / blink code)24 VDC OUT power supply (DCOK LED) = Yes |
|---|
| Status indicators | Operating status and supply |
|---|
| Power supply | Bus connection |
|---|
| X2X Link | Yes, using software |
|---|
| Overload | Yes, using software (outputs) |
|---|
| Power consumption | Max. 0.75 W |
|---|
| Module power supply | 47 µF / 7.5 Ω |
|---|
| I/O power supply | 47 µF |
|---|
| Digital outputs - 24 VDC X2X, OUT power supply | No |
|---|
| X2X Link - 24 VDC X2X, OUT power supply | Yes |
|---|
| X2X Link - Digital outputs | Yes |
|---|
| Remote valve terminal connection for 25-pin DSUB multi-pin connection | 16 valves |
|---|
| CE | Yes |
|---|
| UL | cULus E115267Industrial control equipment |
|---|
| Bus connection | 11-pin |
|---|
| GND pin | 13, 22, 23, 24, 25 |
|---|
| Variant | 11-pin male multipoint connector |
|---|
| Type | High-side driver (source) |
|---|
| Напряжение питания | 24 VDC ±25% |
|---|
| Total nominal current | 1.6 A |
|---|
| Output circuit | Source |
|---|
| Output protection | Protected against short circuit, overload and overtemperature |
|---|
| 0 → 1 | Typ. 150 μs / max. 200 μs |
|---|
| 1 → 0 | Typ. 175 μs / max. 250 μs |
|---|
| Max. output current | 0.1 A |
|---|
| Max. switching frequency | 100 Hz |
|---|
| Horizontal | Yes |
|---|
| Vertical | Yes |
|---|
| Degree of protection per EN 60529 | IP20 |
|---|
| Operation | 5 to 95%, non-condensing |
|---|
| Storage | 5 to 95%, non-condensing |
|---|
| Transport | 5 to 95%, non-condensing |
|---|
| Note | Order 1x 0TB1111.8110 terminal block separately |
|---|
| Installation | 25-pin DSUB, screw mounting, 4-40 UNC |
|---|
| Масса | 56 g |
|---|
| Module dimensions including mounting plates | 63 x 59 x 20 mm (H x W x D) |