B&R Industrial Automation (a Business Unit of ABB) 8BVI0880HCS0.004-1
8BVI0880HCS0.004-1: Integrated uncontrolled standstill and safe stop; Integrated connection for motor holding brake and temperature sensor; 2 slots for ACOPOSmulti plug-in modules
Технические характеристики
| B&R ID code | 0xA64A |
|---|---|
| Cooling and mounting type | Cold plate or feed-through mounting |
| Slots for plug-in modules | 2 |
| CE | Yes |
| Functional safety | Yes |
| UL | cULus E225616Power conversion equipment |
| EAC | Yes |
| KC | Yes |
| Nominal | 5 to 40°C |
| Continuous power consumption | 65 kW |
| Switching frequency 5 kHz | 25 m |
| Switching frequency 10 kHz | 25 m |
| Switching frequency 20 kHz | 25 m |
| DC bus capacitance | 1980 µF |
| Variant | ACOPOSmulti backplane |
| Напряжение питания | 25 VDC ±1.6% |
| Input capacitance | 32.9 µF |
| Max. power consumption | 27 W + PSLOT1+ PSLOT2+ P24 V Out+ PHoldingBrake |
| Quantity | 2 |
| Напряжение питания | 25 VDC * (UDC/ 315) |
| Напряжение питания | 24 VDC ±6% |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
| Continuous power per motor connection | 64 kW |
| Continuous current per motor connection | 88 Aeff |
| Cold plate mounting | 0.75 A/K (from -37°C) |
| Feed-through mounting | 209 mm |
| Starting at 500 m above sea level | 8.8 Aeffper 1000 m |
| Peak current | 176 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Electrical stress of connected motor per IEC TS 60034-25 | Limit value curve A |
| Overload protection | Yes |
| Short circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| U, V, W, PE | M8 threaded bolt |
| Shield connection | Yes |
| Flexible and fine-stranded wires | --- |
| Terminal cable cross section dimension of shield connection | 12 to 50 mm |
| Напряжение питания | 24 VDC +5.8% / -0% |
| Continuous current | 4.2 A |
| Max. internal resistance | 0.15 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 3 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open circuit monitoring | Yes |
| Напряжение питания | Yes |
| Response threshold for open circuit monitoring | Approx. 0.5 A |
| Напряжение питания | 24 VDC +0% / -4% |
| Circuit | Sink |
| Input - Inverter module | Yes |
| Input - Input | Yes |
| Maximum | 55°C |
| Напряжение питания | Approx. 10 mA |
| Low | <5 V |
| High | >15 V |
| Enable 1 → 0, PWM off | Max. 20.5 ms |
| Enable 0 → 1, ready for PWM | Max. 100 µs |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | permittedMax. test pulse length: 500 µs |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Discharge capacitance | 0.44 µF |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Напряжение питания | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 213.5 mm |
| Height | 317 mm |
| Cold plate | 212 mm |
| Масса | Approx. 7.1 kg |
| Module width | 4 |