B&R Industrial Automation (a Business Unit of ABB) 8CVI045E1HCS0.00-1
8CVI045E1HCS0.00-1: Uncontrolled and safe stops integrated; EnDat 2.1 encoder connection; Integrated connections for local I/O nodes; Reduced cabling (daisy chain)
Технические характеристики
| Module type | ACOPOSremote module |
|---|---|
| B&R ID code | 0xC1B0 |
| Power contacts | Max. 20 A at 40°C |
| Cooling and mounting type | Cold plate mounting |
| CE | Yes |
| Functional safety | Yes |
| UL | cULus E225616Power conversion equipment |
| KC | Yes |
| Nominal | 5 to 40°C |
| Continuous power consumption | In preparation |
| Switching frequency 5 kHz | 10 m |
| Switching frequency 10 kHz | 5 m |
| Switching frequency 20 kHz | 5 m |
| DC bus capacitance | 35 µF |
| Variant | M8 connector |
| Maximum | 60°C |
| Напряжение питания | 24 VDC +20% / -25% |
| Input capacitance | In preparation |
| Max. power consumption | 10 W + P24 V Out+ PHolding brake+ PTrigger |
| Quantity | 2 |
| Напряжение питания | 5 V ±5% |
| Continuous current | 1.1 A |
| Fuse protection | Electronic (per pin) |
| 24 VDC, COM | M8 connector |
| Continuous power per motor connection | 1.5 kW |
| Continuous current per motor connection | 4.5 Aeff |
| Starting at 500 m above sea level | 0.45 A per 1,000 m |
| Peak current | 13.5 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Electrical stress of connected motor per IEC TS 60034-25 | Limit value curve A |
| Overload protection | Yes |
| Short circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| U, V, W, PE | 8-pin speedtec connector, size 1 |
| Shield connection | Yes (via connector housing) |
| Max. internal resistance | In preparation |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open circuit monitoring | Yes |
| Напряжение питания | Yes |
| Response threshold for open circuit monitoring | Approx. 0.25 A |
| Напряжение питания | 24 VDC +0% / -4% |
| Type | EnDat 2.1 |
| Cable length | Max. 100 m between two stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Module-side connection | 15-pin female springtec connector |
| Status indicators | UP/DN LEDs |
| Encoder - ACOPOSremote | No |
| Encoder monitoring | Yes |
| Max. encoder cable length | 10 m |
| Load capacity | 250 mA |
| Sense lines | 2, compensation of max. 2x 0.7 V |
| Overload-proof | Yes |
| Short-circuit proof | Yes |
| Signal transmission | RS485 |
| Signal frequency (-3 dB) | DC up to 300 kHz |
| Signal frequency (-5 dB) | DC up to 400 kHz |
| Напряжение питания | 0.5 to 1.25 Vss |
| Напряжение питания | Max. ±7 V |
| Terminating resistor | 120 Ω |
| Resolution | 12-bit |
| Напряжение питания | ≤-0.2 V |
| Напряжение питания | ≥0.2 V |
| Resolution @ 1 VSS | Number of encoder lines * 5700 |
| Accuracy | - |
| Noise | - |
| Data transfer rate | Depends on the configured functionality |
| Circuit | Sink |
| Input - Inverter module | No |
| Input - Input | No |
| Напряжение питания | In preparation |
| Low | <5 V |
| High | >15 V |
| Enable 1 → 0, PWM off | Max. 20.5 ms |
| Enable 0 → 1, ready for PWM | Max. 100 µs |
| Modulation compared to ground potential | In preparation |
| OSSD signal connections | PermissibleMax. test pulse length: 500 µs |
| Rising edge | In preparation |
| Falling edge | In preparation |
| Max. cable length | 30 m |
| ACP10 | V2.35.1 and higher |
| Discharge capacitance | 0.1 µF |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | Yes |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Напряжение питания | III |
| Degree of protection per EN 60529 | IP65 |
| Storage | 5 to 95%, non-condensing |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85%, non-condensing |
| Width | 137 mm |
| Height | 287.2 mm |
| Depth | 131 mm |
| Масса | 4.8 kg |