8EI2X2HWD10.0000-1

B&R Industrial Automation (a Business Unit of ABB) 8EI2X2HWD10.0000-1

8EI2X2HWD10.0000-1

Технические характеристики

Slots for plug-in modules1
Network configurationsTN-S, TN-C-S with grounded star point
Напряжение питания3x 200 VAC to 480 VAC ±10%
Frequency50/60 Hz ±4%
Installed loadMax. 5 kVA
Inrush currentMax. 45 A
Switch-on intervalTyp. 60 s
Integrated line filter per EN 61800-3, category C3No
Power dissipation at device nominal power without braking resistor[(50 + 6.9 * PAVG[kW] + 7.5 * (IAX1[A] + IAX2[A]) + 0.25 * (IBR12[A] + IBR22[A]) + PVSLOT) * 1.1] [W]
DC bus capacitance470 µF
Напряжение питания24 VDC ±25%
Input capacitance5507 µF
Current consumption1.2 A + current for motor holding brake
Quantity2
Continuous power per motor connection1 / 1 kW
Continuous current per motor connection2.2 / 2.2 AEff
Switching frequency 5 kHz75 m
Switching frequency 10 kHz37.5 m
Switching frequency 20 kHz18.75 m
Starting at 500 m above sea level0.22 AEffper 1000 m
Peak current per motor connection6 / 6 AEff
Peak power output2.5 kW
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Overload protectionYes
Short circuit and ground fault protectionYes
Max. output frequency598 Hz
U, V, W, PEMale connector
Shield connectionYes
With wire end sleeves1.5 to 6 mm²
UL/C-UL-US24 to 8 AWG
CSA24 to 8 AWG
Напряжение питанияTyp. 11.4 V
Continuous current1.3 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Overload and short-circuit protectionYes
Open circuit monitoringYes
Напряжение питанияYes
Response threshold for open circuit monitoringApprox. 30 mA
Peak power int./ext.7 kW / 25 kW
Continuous power int./ext.150 W / 2 kW
Minimum braking resistance (ext.)25 Ω
CircuitSink
Input - ACOPOS P3Yes
Input - InputYes
Nominal5 to 40°C
Maximum55°C
Напряжение питанияApprox. 4 mA
Low<5 V
High>15 V
Enable 1 → 0, PWM off2 ms
Enable 0 → 1, ready for PWM0.3 ms
Modulation compared to ground potentialMax. ±38 V
OSSD signal connections0.5 ms
TypeEnDat 2.2
Connections8-pin female mini I/O connector
Status indicatorsNone
Encoder - ACOPOS P3No
Encoder monitoringNo
Max. encoder cable length100 mDepends on the cross section of the power supply wires in the encoder cable
Load capacity300 mA
Short-circuit proofYes
Overload-proofYes
Signal transmissionRS485
Data transfer rate6.25 Mbit/s
Max. power consumption per encoder interfacePENCODER[W] = U24V[V] * (IENCODER[A] * 0.7) + 0.5 W
Rising edge<2 µs
Falling edge<1 µs
ACP10V3.12.1
Hanging verticallyYes
Standing horizontallyIn preparation
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Напряжение питанияIII
Degree of protection per EN 60529IP20
Storage5 to 95%
Transport95% at 40°C
Operation5 to 85%, non-condensing
Width66 mm
Height374 mm
Wall mounting258.5 mm (with 8EXA front cover: 261 mm)
Масса4 kg
Получить предложение по этой позиции