X20DS1319

B&R Industrial Automation (a Business Unit of ABB) X20DS1319

X20DS1319: 4 digital input channels; 4 digital channels, configurable as inputs or outputs; 1 universal counter pair (2 event counters, AB counters or up/down counters); Linear movement generator (A/B, direction/frequency) with up to 2 reference pulses; SSI absolute encoder; NetTime timestamp: Input data, target position, position change, edge change, counter change; This module is a multifunction digital signal processor module. It can be used extremely flexibly for a wide variety of tasks involving digital signal processing or digital signal generation. Two primary example applications include controlling stepper output stages with pulse and direction signals or using as encoder emulation. In this application, for example, frequency inverters or servo axes with the speed follow function can follow a real or virtual master axis.; An additional essential feature is the module's integrated timestamp function. It allows counter ramps curves to be generated virtually independently of bus cycle times during encoder emulation, for example. Only the target counter value and moment when it should be reached are transferred. The module automatically generates the corresponding counter values at the appropriate time, precisely in microsecond resolution and independently of the bus clock.

Технические характеристики

I/O module4 digital input channels, 4 digital channels configurable as inputs or outputs, 1 universal counter pair (2 event counters, AB counter or up/down counter), linear movement generator (A/B, direction/frequency) with up to two reference pulses, SSI absolute encoder, relative or absolute moments of input edges with μs resolution, time-triggered I/O, I/O oversampling
B&R ID code0x2547
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator
Bus0.01 W
Internal I/O1.5 W
Additional power dissipation caused by actuators (resistive) [W]-
Type of signal linesShielded lines must be used for all signal lines.
CEYes
UKCAYes
ATEXZone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X
ULcULus E115267Industrial control equipment
HazLoccCSAus 244665Process control equipmentfor hazardous locationsClass I, Division 2, Groups ABCD, T5
DNVTemperature:B(0 to 55°C)Humidity:B(up to 100%)Vibration:B(4 g)EMC:B(bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33BTemperature: 5 - 55°CVibration: 4 gEMC: Bridge and open deck
KCYes
QuantityUp to 4, configuration as input or output using software
Encoder outputs24 V, asymmetrical (A/B, direction/frequency)
Counter size16/32-bit
Напряжение питания24 VDC
Напряжение питания24 VDC -15% / +20%
Input current at 24 VDCApprox. 1.3 mA
Input circuitSink
Hardware≤2 µs
Software-
Input resistance18.4 kΩ
Additional functionsClock for SSI absolute encoder, linear movement generator
Input frequencyMax. 100 kHz
Low<5 VDC
High>15 VDC
Overload characteristics of encoder power supplyShort-circuit proof, overload-proof
Напряжение питания500 Veff
Max. transfer rate125 kbit/s
Encoder power supplyModule-internal, max. 600 mA
Operating modes2x event counter, up/down counter, AB counter
Encoder inputs24 V, asymmetrical
AB counter4x
Event counters2x
Up/Down counter2x
Signal formSquare wave pulse
VariantPush / Pull / Push-Pull
Напряжение питания24 VDC -15% / +20%
Nominal output current0.1 A
Total nominal current0.4 A
Output circuitSink and/or source
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
Diagnostic statusOutput monitoring
Leakage current when the output is switched offMax. 25 µA
Напряжение питания<0.9 V at 0.1 A nominal current
Peak short-circuit current<10 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
0 → 1<2 µs
1 → 0<2 µs
Resistive loadMax. 125 kHz
Inductive loadSee section "Switching inductive loads".
Напряжение питанияSwitching voltage + 0.6 VDC
Electrical isolationChannel isolated from busChannel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating-
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately.Order 1x bus module X20BM11 separately.
Pitch12.5+0.2mm