X20SC0842: 8 safe digital inputs, sink circuit; 4 pulse outputs; Software input filter configurable for each channel; 4 safe digital outputs, output type A with 3 A, source circuit; 2 safe digital outputs, output type B with 50 mA, source circuit; Integrated output protection; The module is equipped with 8 safe digital inputs and 6 safe digital outputs. It is designed for a nominal voltage of 24 VDC.; The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3.; The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.; The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur.; This module is designed for X20 12-pin terminal blocks.

Категории:

Технические характеристики

I/O module8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD <500 µs, 2 safe type B2 digital outputs, 24 VDC, 50 mA, OSSD <500 µs
B&R ID code0xE7F9
Automation Studio4.0 or later
Automation Runtime4.0 or later
SafeDESIGNER3.4.0 or later
Safety Release1.7 or later
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using status LED and software
OutputsYes, using status LED and software
InputsYes, using status LED and software
ScopeModule
FunctionModule function
Standalone modeNo
Max. I/O cycle time1 ms
Bus0.4 W
Internal I/O2.5 W
Channel - BusYes
Channel - ChannelNo
CEYes
Functional safetyEN 50156-1:2004
ATEXZone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X
ULcULus E115267Industrial control equipment
DNV GLIn preparation
EACYes
MTTFD2500 years
Mission timeMax. 20 years
Module<1*10-10
openSAFETY wiredNegligible
openSAFETY wireless<1*10-14* Number of openSAFETY packets per hour
PFD<2*10-5
Proof test interval (PT)20 years
CategoryCat. 3 if parameter "Disable OSSD = Yes - Warning",Cat. 4 if parameter "Disable OSSD = No"
PLPL d if parameter "Disable OSSD = Yes - Warning",PL e if parameter "Disable OSSD = No"
DC>60% if parameter "Disable OSSD = Yes - Warning",>94% if parameter "Disable OSSD = No"
SIL CLSIL 2 if parameter "Disable OSSD = Yes - Warning",SIL 3 if parameter "Disable OSSD = No"
SFF>60% if parameter "Disable OSSD = Yes - Warning",>90% if parameter "Disable OSSD = No"
Напряжение питания24 VDC
Напряжение питания24 VDC -15% / +20%
Integrated protectionReverse polarity protection
VariantPush-Pull
Input characteristics per EN 61131-2Type 1
Hardware≤150 µs
SoftwareConfigurable between 0 and 500 ms
Input circuitSink
Напряжение питания24 VDC -15% / +20%
Input current at 24 VDCMax. 3.28 mA
Input resistanceMin. 7.33 kΩ
Error detection time1 s
Напряжение питания500 Veff
Low<5 VDC
High>15 VDC
Cable length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded lineMax. 400 m with shielded line
Nominal output current50 mA
Total nominal current200 mA
Output protectionShutdown of individual channels in the event of overload or short circuit
Напряжение питанияMax. 45 VDC
Error detection1 s
Peak short-circuit current0.5 A for 120 µs
Leakage current when the output is switched off0.1 mA
Напряжение питания≤4 VDC
Напряжение питанияI/O power supply minus residual voltage
Max. switching frequency100 Hz
Test pulse lengthMax. 500 µs
Max. capacitive load100 nF
IOUT<100 µA
IGND<50 mA
Short-circuit current15 mAeff
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Horizontal mounting orientation0 to 60°C
Vertical mounting orientation0 to 50°C
DeratingSee section "Derating".
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 2x safety-keyed terminal block separately.Order 1x safety-keyed bus module separately.
Pitch25+0.2mm