X20SO4110: 4 safe digital outputs with 0.5 A; Source circuit; Output type A; Current monitoring; Open circuit detection; Integrated output protection; This module is equipped with 4 safe digital outputs. The nominal output current is 0.5 A.; The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3.; The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection.; This module is designed for X20 12-pin terminal blocks.
Категории:
Технические характеристики
| I/O module | 4 safe type A digital outputs, with current monitoring, 24 VDC, 0.5 A, OSSD <500 µs |
|---|---|
| B&R ID code | 0x1DBE |
| Automation Studio | 3.0.71 or later |
| Automation Runtime | 2.95 or later |
| SafeDESIGNER | 2.58 or later |
| Safety Release | 1.1 or later |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using status LED and software |
| Outputs | Yes, using status LED and software |
| Scope | Module |
| Function | Module function |
| Standalone mode | No |
| Max. I/O cycle time | 800 µs |
| Bus | 0.25 W |
| Internal I/O | 1.3 W |
| Channel - Bus | Yes |
| Channel - Channel | No |
| CE | Yes |
| Functional safety | EN 50156-1:2004 |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL | cULus E115267Industrial control equipment |
| HazLoc | cCSAus 244665Process control equipmentfor hazardous locationsClass I, Division 2, Groups ABCD, T5 |
| DNV GL | Temperature:A(0 - 45°C)Humidity:B(up to 100%)Vibration:A(0.7 g)EMC:B(bridge and open deck) |
| LR | ENV1 |
| KR | Yes |
| EAC | Yes |
| KC | Yes |
| Category | Cat. 3 if parameter "Disable OSSD = Yes - Warning",Cat. 4 if parameter "Disable OSSD = No" |
| PL | PL d if parameter "Disable OSSD = Yes - Warning",PL e if parameter "Disable OSSD = No" |
| DC | >60% if parameter "Disable OSSD = Yes - Warning",>94% if parameter "Disable OSSD = No" |
| MTTFD | 2500 years |
| Mission time | Max. 20 years |
| SIL CL | SIL 2 if parameter "Disable OSSD = Yes - Warning",SIL 3 if parameter "Disable OSSD = No" |
| SFF | >60% if parameter "Disable OSSD = Yes - Warning",>90% if parameter "Disable OSSD = No" |
| Module | <1*10-10 |
| openSAFETY wired | Negligible |
| openSAFETY wireless | <1*10-14* Number of openSAFETY packets per hour |
| PFD | <2*10-5 |
| Proof test interval (PT) | 20 years |
| Напряжение питания | 24 VDC |
| Напряжение питания | 24 VDC -15% / +20% |
| Integrated protection | Reverse polarity protection |
| Variant | FET, 1x positive switching, 1x negative switching, type A, output level readable, open-circuit detection |
| Nominal output current | 0.5 A |
| Total nominal current | 2 A |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads |
| Напряжение питания | Max. 90 VDC |
| Open-circuit detection | Via internal current measurement,output current <10 mA: Signal "CurrentOK" = FALSE,output current 10 to 50 mA: Signal "CurrentOK" = Undefined,output current >50 mA: Signal "CurrentOK" = TRUE |
| Error detection time | 1 s |
| Напряжение питания | 500 Veff |
| Peak short-circuit current | Max. 12 A |
| Leakage current when the output is switched off | <10 µA |
| Напряжение питания | <120 mVDC at 0.5 A nominal current without OSSD |
| Напряжение питания | I/O power supply minus residual voltage |
| Max. switching frequency | 1000 Hz |
| Test pulse length | Max. 500 µs |
| Time between two test pulses | Min. 49.5 ms |
| Max. capacitive load | 100 nF |
| Horizontal | Yes |
| Vertical | Yes |
| Installation elevation above sea level | 0 to 2000 m, no limitation |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | 0 to 60°C |
| Vertical mounting orientation | 0 to 50°C |
| Derating | See section "Derating". |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x safety-keyed terminal block separately.Order 1x safety-keyed bus module separately. |