Beckhoff Automation GmbH & Co. KG EL2652
EL2652 EtherCAT Terminal, 2-channel relay output, 230 V AC, 300 V DC, 1 A
Категории:
Технические характеристики
| Connection technology | relay output |
|---|---|
| Number of outputs | 2 x change-over |
| Напряжение питания | 250 V AC, 300 V DC |
| Напряжение питания | 230 V AC (max. switching voltage 250 V AC/300 V DC) |
| Load type | resistive, inductive, lamp load |
| Distributed clocks | â |
| Resistive switching current | 1 A AC/DC (at 40 V DC), 0.15 A DC (at 300 V DC), for UL: 1 A, max. 230 V AC |
| Minimum permitted load | 100 mA at 12Â V |
| Current consumption E-bus | 180 mA |
| Current consumption power contacts | â |
| Max. switching frequency | 6/min. (at rated load) |
| Operating cycles mech. (min.) | 5 x 10 6 |
| Operating cycles electr. (min.) | 1 x 10 6 (1Â A/250Â VÂ AC resistive load) |
| Electrical isolation | 1.5 kV (E-bus/field potential); 2.5 kV rated surge voltage, overvoltage category III |
| Special features | reverse switching realizable |
| Масса | approx. 55 g |
| Operating temperature | -25â¦+55°C |
| Storage temperature | -40â¦+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/variable |
| Pluggable wiring level | for all ESxxxx terminals |
| Approvals/markings | CE, UL, DNV |
| Description | The EL2652 output terminal has two relays each with a changeover contact, which can be used universally for the switching of mains voltage consumers of 230Â VÂ AC or 300Â VÂ DC. The EL2652 features potential-free contacts. The signal state of the EtherCAT |