Beckhoff Automation GmbH & Co. KG EL6910
EL6910 EtherCAT Terminal communication interface, TwinSAFE Logic
Категории:
Технические характеристики
| Specification | link unit between safe input and output signals |
|---|---|
| Protocol | TwinSAFE/Safety over EtherCAT |
| Cycle time | approx. 1Â ms/according to project size |
| Время отклика | ⤠watchdog time (parameterizable) |
| Current consumption power contacts | â |
| Current consumption E-bus | typ. 160 mA |
| Installation position | horizontal |
| Safety standard | ENÂ ISOÂ 13849-1:2015 (Cat. 4, PL e) and ENÂ 61508:2010 (SIL 3) |
| Масса | approx. 50 g |
| Protection rating | IP20 |
| Ex marking | ATEX: II 3G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc cFMus: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx ec IIC T4 Gc |
| Description | The EL6910 represents the new generation of dedicated safety controllers. While the EL6900 as its predecessor provided only function blocks based on Boolean values, the EL6910 offers a wide variety of certified function blocks that enable the safe |