Datasensing S.r.l. IS-12-O1-S2
Inductive Proximity Sensor ø12 short stainless steel - double range flush 4 mm - pnp no 3 wires- M12
Категории:
Технические характеристики
| Nominal sensing distance | 4mm |
|---|---|
| Operanting distance | 0…3,24mm |
| Standard target | 12x12mm FE360 |
| Correction Factor | copper: 0,2…0,5 / aluminium: 0,3…0,5 / brass: 0,4…0,6 / stainelss steel: 0,7…0,9 |
| Repeat Accuracy | < 3% (UB 24V Ta=23°C ±5°C) |
| Hysteresis | < 10% |
| Description | M12 short case flush mount |
| Functions | Proximity |
| Output type | PNP |
| Output Function | NO |
| Switching frequency | 500Hz |
| Время отклика | 1 |
| Напряжение питания | 10...30Vdc |
| No-Load supply current | ≤ 10mA |
| Load current | 100mA |
| Напряжение питания | ≤ 1,2V @100mA |
| Max ripple content | ≤ 10% |
| LED indicators | Yellow LED output state |
| Time delay before availability | ≤ 75ms |
| Short-circuit protection | Yes |
| Reverse Polarity Protection | Yes |
| Emission | ≥100kHz |
| Protection against inductive loads | Yes |
| Dimensions | Ø12x48 |
| Mounting | Shielded |
| Материал | Stainless steel |
| Материал | Stainless steel |
| Connections | M12 Plug |
| Материал | LCP |
| Tightening torque | 6Nm |
| Diameter/Dimension | M12 |
| Approvals | CE cULus ECOLAB DIVERSEY |
| Supplied Accessories | 2 nuts M12x1 |
| Generical Data - Dimensions | Ø12 / L = 48mm |
| Operating Temperature | -25°C…+70°C |
| Mechanical Protection | IP69K |