Datasensing S.r.l. SLS-M10-1708-E
Very Long range 17/8p Enhanced
Категории:
Технические характеристики
| Angular resolution | 0,1° .. 0,059° |
|---|---|
| Safety range ( min) | 0,05m |
| Safety range (max) [ detection capability] | = 10m |
| warning range (max) | 40m |
| Detectable target remission | 1,8% … 1000% |
| N°of simultaneous safety zone (max) | 3 |
| N°of simultaneous warning zone (max) | 2 |
| N°of zone set (max) | 20 (with M12-17 poles connector); 70 (with M12-17 poles + M12-8 poles connectors) |
| N°of reference point set (max) | 70 |
| Время отклика | Min 62 ms @5,5 m; 84 ms @9 m; 103 ms @10 m programmable |
| Tolerance Zone | 100mm |
| Supplement for retroreflectors on scan plane in front of a safety zone | 200mm |
| Type | 3 (EN ISO 13849-1) |
| SIL | 2 (IEC61508) |
| Cat. | 3 (EN ISO 13849-1) |
| PL | d (EN ISO 13849-1) |
| TM (Mission Time) | 20 years (EN ISO 13849-1) |
| Configurable Inputs max number | 12 |
| Configurable Inputs/Output max number | 4 |
| Configurable Output max number | 2 |
| Power Supply | 16,8v <= Vdc <= 28,8v |
| Power consumption | 8 W @24 V, Single device, without load |
| Protection class | III (EN/IEC 61140) |
| Dimensions | 102 x 113 x 152 mm |
| Материал | Metal - Aluminium / PMMA |
| Материал | Painted alumininium / PC |
| Материал | PMMA |
| Network Interfaces | 10/100 Mbit/s Ethernet |
| Configuration and monitoring interfaces | DL Sentinel 5.0 (with Optima Tune Technology) |
| LED indicators | OSSD / Warning / Interlock |
| Humidity | 15 ... 95 % |
| Enclosure | IP 65 (EN 60529) |
| Operating Temperature | -10 ... 50 °C |
| Storage temperature | -20 ... 70 °C |
| Vibration Resistance | According to IEC 61496-1 (4.3.3.1;4.3.3.2;5.4.4.1) Class 3M7 (Stationary Use) Class 5M1 (Ground vehicle Installation) |
| Shock Resistance | According to IEC 61496-1 (4.3.3.1;4.3.3.3;5.4.4.2) IEC 61496-3 (5.4.4); IEC 60068-2-75 Class 3M7 (Stationary Use) Class 5M1 (Ground vehicle Installation) |
| Laser Wavelength | 905 nm |
| Mono/Color | 3ns |
| Laser class/Laserklass | CLASS 1 (EN 60825-1:2014) |
| Generic Alarm | available |
| Clean Window Alarm | available |
| Muting enable | available |
| Muting | available |
| Override | available |
| Dust Filtering | available |
| EDM (External Device Monitoring) | available |
| Partial Muting | available |
| Pre-alarm (warning) | available |
| Advanced Data transfer protocol | available |
| Reset( restart cycle) | available |
| Manual/automatic restart | available |
| Shut-off (mute) | available |
| Encoder input | available |
| Start-up external trigger | available |