SLS-M5-PP-BA

Datasensing S.r.l. SLS-M5-PP-BA

Profinet / Profisafe command integration, long range

  • Бренд: Datasensing S.r.l.
  • Артикул (MPN): SLS-M5-PP-BA
  • Статус производства: Не определён

Категории:

Технические характеристики

Detection capability0
Angular resolution0,1°
Safety range ( min)0,05 m
Safety range (max) [ detection capability]2,5m[30mm]; 3m[40mm]; 4m[50mm]; 5,5m[70,150mm]
warning range (max)40 m
Detectable target remission1,8% .. ""1000%""
N°of simultaneous safety zone (max)8
N°of simultaneous warning zone (max)7
N°of zone set (max)70
N°of reference point set (max)70
Время отклика94 ms - 1750 ms (Fast Mode), 105 ms - 2065 ms (Standard Mode)
Tolerance Zone100 mm
Supplement for retroreflectors on scan plane in front of a safety zone200 mm
Type3 (EN 61496-1)
SILSIL 2 (IEC 61508) SIL 2 (EN 62061)
Cat.(EN ISO 13849-1)
PFHd2.24 x 10-8
MTTFd61 years
TM (Mission Time)20 years (EN ISO 13849-1)
Power Supply16.8 Vdc ... 28.8 Vdc
Power consumption8.5 W @24 V, no digital I/O connected
Protection classIII (EN/IEC 61140)
Dimensions102x113x152 mm
МатериалMetal - Aluminium / PMMA
МатериалPainted alumininium / PC
МатериалPMMA
N° of configurable input (max)5
N° of configurable output (max)4
Network Interfaces10/100 Mbit/s Ethernet (3X)
PROFINET specificationV2.43
PROFIsafe specificationV2.6.1 & 2.4 (w/o iPar) / Conformance class B
GSDML specificationV2.43
Power and I/0M12 male type A connector - 8 poles
Ethernet to GUI / Data transmissionM12 male type D connector - 4 poles
Profinet / ProfisafeM12 male type D connector - 4 poles (2X)
Configuration and monitoring interfacesDL Sentinel 4.0.x
LED indicatorsTX: Green (Power ON), Yellow (Emission range) Red (Test, failure, Firmware ongoing update), Blue (Emission range, Firmware update completed) RX: Green (Power ON), Yellow (Status output, Connection and teach-in active) Red (Hardware Errors, Invalid con
Humidity95% max non-condensing
EnclosureIP65
Operating Temperature-10 ... 50 °C
Storage temperature-20 ... 70 °C
Vibration ResistanceAccording to IEC 61496-1 (4.3.3.1;4.3.3.2;5.4.4.1) Class 3M7 (Stationary Use) Class 5M1 (Ground vehicle Installation)
Shock ResistanceAccording to IEC 61496-1 (4.3.3.1;4.3.3.3;5.4.4.2) IEC 61496-3 (5.4.4); IEC 60068-2-75 Class 3M7 (Stationary Use) Class 5M1 (Ground vehicle Installation)
Laser Wavelength905 nm
Laser Pulse duration3 ns
Laser class/LaserklassCLASS 1 (EN 60825-1:2014)
Generic AlarmAvailable
Clean Window AlarmAvailable
Muting enableNot Available
MutingAvailable
OverrideAvailable
Dust FilteringAvailable
EDM (External Device Monitoring)Not Available
Partial MutingAvailable
Pre-alarm (warning)Available
Advanced Data transfer protocolAvailable
Reset( restart cycle)Available
Manual/automatic restartAvailable
Shut-off (mute)Available
Dynamic Reference PointsAvailable
Encoder inputNot Available
Получить предложение по этой позиции