R3G250-RR09-P1

ebm-papst Mulfingen GmbH & Co. KG R3G250-RR09-P1

EC centrifugal fan - RadiCal

Категории:

Технические характеристики

Масса4,1 kg
Motor size84
Size250 mm
Rotor surfacePainted black
МатериалDie-cast aluminum
МатериалPA plastic UL94 V0
Number of blades7
Direction of rotationClockwise, viewed toward rotor
Degree of protectionIP55
Insulation class"F"
Moisture (F) / Environmental (H) protection classH3
Max. permitted ambient temp. for motor (transport/storage)+80 °C
Min. permitted ambient temp. for motor (transport/storage)-40 °C
Installation positionShaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holesOn rotor side
ModeS1
Motor bearingBall bearing / (sealed)
Technical features- Output 10 VDC, max. 10 mA - Operation and alarm display - Alarm relay - Run monitoring - Power limiter - Motor current limitation - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Overvoltage detection - Thermal overload protection for electronics/motor - Line undervoltage detection - Reverse polarity protection
EMC regulationsaccording to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)<= 0,25 mA
Motor protectionThermal switch auto reset, internally connected
with cableLateral
Protection class assignmentI; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation.
Conformity with standardsEN 15085-1, CPC3; EN 45545-2, HL3; EN 50155; EN 61373, Cat. 1B
Comment on CEEcodesign Directive 2009/125/EC + Fan Regulation (EC) No. 327/2011 does not apply, as use only in means of transport for transporting persons or goods.
ApprovalEAC / CCC
CommentIf supply potential (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation, meaning they then have only basic insulation|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay. EMC regulation: EN 50121-3-2 in preparation; speed limit 4000 rpm
Напряжение питанияDC
Напряжение питания110 V
Напряжение питания77 .. 138 V
Type of data definitionmaximum load
Speed3800 min-1
Power input540 W
Current draw4,9 A
Рабочая температура60 °C
Получить предложение по этой позиции