R3G355-RJ76-N1

ebm-papst Mulfingen GmbH & Co. KG R3G355-RJ76-N1

EC centrifugal fan - RadiCal

Категории:

Технические характеристики

Масса9,2 kg
Motor size112
Size355 mm
Rotor surfacePainted black
МатериалDie-cast aluminum
МатериалPA plastic UL94 V0
Number of blades6
Direction of rotationClockwise, viewed toward rotor
Degree of protectionIP55
Insulation class"F"
Moisture (F) / Environmental (H) protection classH3
Max. permitted ambient temp. for motor (transport/storage)+80 °C
Min. permitted ambient temp. for motor (transport/storage)-40 °C
Installation positionShaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holesOn rotor side
ModeS1
Motor bearingBall bearing / (sealed)
Technical features- Output 10 VDC, max. 10 mA - Alarm relay - Integrated PID controller - Run monitoring - Power limiter - Motor current limitation - Emergency operation - PFC, passive - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Overvoltage detection - Thermal overload protection for electronics/motor - Line undervoltage / phase failure detection
EMC regulationsaccording to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)<= 3,5 mA
Motor protectionThermal switch auto reset, internally connected
with cableVariable
Protection class assignmentI; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation.
Conformity with standardsEN 15085-1, CPC3; EN 45545-2, HL3; EN 50155; EN 61373, Cat. 1B
Comment on CEEcodesign Directive 2009/125/EC + Fan Regulation (EC) No. 327/2011 does not apply, as use only in means of transport for transporting persons or goods.
ApprovalEAC / CCC
CommentPrerequisite for operation is a Class 1 vehicle electrical system architecture according to EN 50533. If supply voltage (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation, meaning they then have only basic insulation.|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay. EN 50121-3-2: 2015 in preparation
Phase3~
Напряжение питанияAC
Напряжение питания400 V
Напряжение питания380 .. 480 V
Frequency50/60 Hz
Type of data definitionmaximum load
Speed2400 min-1
Power input1100 W
Current draw1,7 A
Рабочая температура60 °C
Получить предложение по этой позиции