R3G400-BE08-N1

ebm-papst Mulfingen GmbH & Co. KG R3G400-BE08-N1

EC centrifugal fan

Категории:

Технические характеристики

Масса15,24 kg
Motor size112
Size400 mm
Rotor surfacePainted black
МатериалDie-cast aluminum, painted gray
МатериалSheet aluminum
Number of blades7
Direction of rotationClockwise, viewed toward rotor
Degree of protectionIP55
Insulation class"F"
Moisture (F) / Environmental (H) protection classH3
Max. permitted ambient temp. for motor (transport/storage)+80 °C
Min. permitted ambient temp. for motor (transport/storage)-40 °C
Installation positionShaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holesOn rotor side
ModeS1
Motor bearingBall bearing / (sealed)
Technical features- Operation and alarm display with LED - External 15-50 VDC input (parameterization) - Alarm relay - Integrated PI controller - Configurable inputs/outputs (I/O) - Run monitoring - MODBUS V6.3 - Motor current limitation - RS-485 MODBUS-RTU - Soft start - Voltage output 3.3-24 VDC, Pmax = 800 mW - Control interface with SELV potential safely disconnected from the mains - Thermal overload protection for electronics/motor - Line undervoltage / phase failure detection
EMC regulationsaccording to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)<= 3,5 mA
Electrical hookupTerminal box
Motor protectionElectronic motor protection
Protection class assignmentI; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation.
Conformity with standardsEN 15085-1, CPC3; EN 45545-2, HL3; EN 50155; EN 61373, Cat. 1B
Comment on CEEcodesign Directive 2009/125/EC + Fan Regulation (EC) No. 327/2011 does not apply, as use only in means of transport for transporting persons or goods.
ApprovalEAC
CommentA prerequisite for operation is a Class 1 vehicle electrical system architecture according to EN 50533; if supply potential (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation and they then have only basic insulation|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay. EMC regulation: EN 50121-3-2 in preparation
Phase3~
Напряжение питанияAC
Напряжение питания400 V
Напряжение питания380 .. 480 V
Frequency50/60 Hz
Type of data definitionmaximum load
Speed2400 min-1
Power input2400 W
Current draw3,7 A
Рабочая температура60 °C