W3G350-CT81-P1

ebm-papst Mulfingen GmbH & Co. KG W3G350-CT81-P1

EC axial fan - HyBlade

Категории:

Технические характеристики

Масса4,62 kg
Motor size74
Size350 mm
Rotor surfaceGalvanized
МатериалDie-cast aluminum, painted black
МатериалPress-fitted sheet steel blank, sprayed with PP plastic
МатериалStainless steel
МатериалSheet steel, galvanized and coated with black plastic (RAL 9005)
Number of blades5
Airflow directionA
Direction of rotationClockwise, viewed toward rotor
Degree of protectioncustomer-specific
Insulation class"B"
Moisture (F) / Environmental (H) protection classH3
Max. permitted ambient temp. for motor (transport/storage)+80 °C
Min. permitted ambient temp. for motor (transport/storage)-40 °C
Installation positionShaft horizontal or rotor on top; rotor on bottom on request
Condensation drainage holesNone
ModeS1
Motor bearingBall bearing
Technical features- Output 10 VDC, max. 10 mA - Alarm relay - Power limiter - Motor current limitation - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Overvoltage detection - Thermal overload protection for electronics - Line undervoltage detection - Reverse polarity protection
EMC regulationsaccording to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)<= 3,5 mA
Motor protectionElectronic motor protection
with cableLateral
Protection class assignmentI; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation.
Conformity with standardsEN 45545-2, HL3 outdoor; EN 50155; EN 61373, Cat. 1B
Comment on CEEcodesign Directive 2009/125/EC + Fan Regulation (EC) No. 327/2011 does not apply, as use only in means of transport for transporting persons or goods.
ApprovalEAC
CommentIf voltage (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation, meaning they then have only basic insulation|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay.
Напряжение питанияDC
Напряжение питания110 V
Напряжение питания77 .. 138 V
FrequencyDC Hz
Type of data definitionmaximum load
Speed1400 min-1
Power input150 W
Current draw1,4 A
Max. back pressure90 Pa
Рабочая температура60 °C
Получить предложение по этой позиции