W3G800-KH94-01

ebm-papst Mulfingen GmbH & Co. KG W3G800-KH94-01

EC axial fan - AxiBlade

Категории:

Технические характеристики

Масса32 kg
Motor size112
Size800 mm
Rotor surfacePainted black
МатериалPP plastic
МатериалDie-cast aluminum, painted black
МатериалPress-fitted sheet steel blank, sprayed with PP plastic
МатериалSheet steel, galvanized and coated with black plastic (RAL 9005)
МатериалSteel, coated with black plastic (RAL 9005)
Number of blades5
Airflow directionV
Direction of rotationClockwise, viewed toward rotor
Degree of protectionIP55
Insulation class"F"
Рабочая температураOccasional start-up at temperatures between -40°C and -25°C is permitted. For continuous operation at ambient temperatures below -25°C (such as refrigeration applications), use must be made of a fan design with special low-temperature bearings.
Moisture (F) / Environmental (H) protection classH2
Max. permitted ambient temp. for motor (transport/storage)+80 °C
Min. permitted ambient temp. for motor (transport/storage)-40 °C
Installation positionShaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holesOn rotor side
ModeS1
Motor bearingBall bearing / (sealed)
Technical features- Output 10 VDC, max. 10 mA - Operation and alarm display - External 24 V input (parameter setting) - Alarm relay - Integrated PID controller - Motor current limitation - PFC, passive - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Thermal overload protection for electronics/motor - Line undervoltage / phase failure detection
EMC immunity to interferenceAccording to EN 61000-6-2 (industrial environment)
EMC circuit feedbackAccording to EN 61000-3-2/3
EMC interference emissionAccording to EN 61000-6-3 (household environment)
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)<= 3,5 mA
Electrical hookupTerminal box
Motor protectionThermal switch auto reset, internally connected
Protection class assignmentI; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation.
Conformity with standardsEN 61800-5-1 / CE
ApprovalCCC / CSA C22.2 No. 77 + CAN/CSA-E60730-1 / UL 1004-7 + 60730-1 / EAC
CommentConformity with standard EN 60335-1 on request
Phase3~
Напряжение питанияAC
Напряжение питания400 V
Напряжение питания380 .. 480 V
Frequency50/60 Hz
Type of data definitionmaximum load
Speed780 min-1
Power input830 W
Current draw1,3 A
Max. back pressure120 Pa
Рабочая температура60 °C
Получить предложение по этой позиции