Технические характеристики

according to EN 60947-5-210 %
Напряжение питания0.25 ... 8 A
Screw terminals0.25 ... 2.5 mm²
U B21 ... 24 ... 27 V DC regulated, residual ripple<5%
EMC protection requirementsAcc. to EN IEC 60947-5-3
(with relay energized)150 mA (without taking into account the load currents at the monitoring outputs)
Current via feedback loop5 ... 8 ... 10 mA
Degree of contamination (external, according to EN 60947-1)2
permissible resistance in feedback loopmax. 600 Ω
LOW0 ... 2 V DC
HIGH15 ... UB V DC
Electrical connection values - HIGH5 ... 8 ... 10 mA
Output typeSemiconductor output, n-switching, short circuit-proof
Напряжение питания0 ... 1 V DC
Output currentmax. 20 mA
external (safety circuit) according to EN 60269-16 AgG or 6 A circuit breaker (characteristic B or C)
Electrical connection values - Output typeRelay contacts, floating
rated conditional short-circuit current100 A
Напряжение питания250 V
Напряжение питания4 kV
(between the operating points of both relays)max. 25 ms
AC-1260V 0.3A
Electrical connection values - AC-1230V 6A
DC-1230V 6A
DC-1324V 3A
Electrical connection values - DC-1260V 0.3A
AC-15230V 2A
Напряжение питания1 ... 300 mA for AC/DC 21 ... 60 V
Connection typeScrew terminals
Number of read headsmax. 4 read heads can be connected
Ready delay10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
Switching frequencymax. 0.25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the actuating range, e.g. with a door open, until the feedback loop is closed.)
Storage temperature-25 ... 70 °C
not condensingmax. 80 % rH
between evaluation unitsmin. 10 mm
Mounting typeMounting rail TH 35 (EN IEC 60715)
after change in the actuation status, 4 active actuatorsmax. 450 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 750 ms. After a brief actuation<0.8 s, the switch-on delay can increase to max. 3 s.)
after change in the actuation status, 2 active actuatorsmax. 290 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 750 ms. After a brief actuation<0.8 s, the switch-on delay can increase to max. 3 s.)
after change in the actuation status, 1 active actuatormax. 210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 750 ms. After a brief actuation<0.8 s, the switch-on delay can increase to max. 3 s.)
after change in the actuation status, 3 active actuatorsmax. 370 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 750 ms. After a brief actuation<0.8 s, the switch-on delay can increase to max. 3 s.)
Start button response delay (for Manual start operating mode)200 ... 300 ms
Start button actuating duration (for Manual Start operating mode)min. 250 ms
Degree of protectionIP20
at U B = 24 V DC-20 ... 55 °C
Dwell timemin. 3 s (The dwell time is the time that the actuator must be outside the actuating range.)
HousingPlastic PA6.6
Number of safety contacts2 Relay with internally monitored contacts
Operating cycles (relay)10 x 10⁶
with center offset m=020 mm (for mounting the read head and actuator in an aluminum profile 45 x 45 mm)
Secured switch-off distance s ar45 mm
In combination with read head CES-A-LSP-05V-104966 and actuator CES-A-BSP-104970 - with center offset m=0min. 10 mm (for mounting the read head and actuator in an aluminum profile 45 x 45 mm)
Switching hysteresis1 ... 4 mm (for mounting the read head and actuator in an aluminum profile 45 x 45 mm)
Minimum distance for side approach directionmin. 3 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935 - with center offset m=09 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935 - Secured switch-off distance s ar21 mm
in z direction (with center offset x,y = 0), in y direction (with center offset x,z = 0)15 mm (for surface mounting of the read head and the actuator)
in y direction100 mm
in x or z direction50 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600 - in z direction (with center offset x,y = 0), in y direction (with center offset x,z = 0)min. 10 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600 - Switching hysteresis1 ... 4 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20 - Minimum distance for side approach directionmin. 4 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20 - with center offset m=09 mm (for surface mounting of the read head in metal and metal-free mounting of the actuator)
for side approach direction (distance in x direction 8 mm)22 mm (for surface mounting of the read head and the actuator)
with vertical approach direction (center offset m = 0)15 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA - Secured switch-off distance s ar47 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA - for side approach direction (distance in x direction 8 mm)min. +/- 18 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA - with vertical approach direction (center offset m = 0)min. 10 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935 - Minimum distance for side approach directionmin. 5 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935 - with center offset m=016 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935 - Secured switch-off distance s ar32 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840 - Minimum distance for side approach directionmin. 3 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840 - with center offset m=08 mm (for surface mounting of the read head in metal and metal-free mounting of the actuator)
between read headsmin. 50 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 - between read headsmin. 160 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730 - in z direction (with center offset x,y = 0), in y direction (with center offset x,z = 0)19 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730 - in x or z direction50 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730 - in y direction100 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730 - Switching hysteresis4 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20 - Minimum distance for side approach directionmin. 4 mm (on mounting in non-metallic environment)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20 - with center offset m=016 mm (on mounting in non-metallic environment)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20 - Secured switch-off distance s ar33 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20 - Switching hysteresis0.5 ... 2 mm (on mounting in non-metallic environment)
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB - Minimum distance for side approach directionmin. 1.2 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB - with center offset m=05 mm (for surface mounting of the read head in steel)
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB - Secured switch-off distance s ar10 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB - Switching hysteresis0.1 ... 0.3 mm (for surface mounting of the read head in steel)
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA - with vertical approach direction (center offset m = 0)23 mm (for surface mounting of the read head and the actuator)
for side approach direction (distance in x direction 10 mm)28 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA - Secured switch-off distance s ar60 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA - for side approach direction (distance in x direction 10 mm)min. +/- 24 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA - Minimum distance for side approach directionmin. 3 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA - with center offset m=015 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA - Secured switch-off distance s ar26 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA - Switching hysteresis0.5 ... 2 mm (for surface mounting of the read head and the actuator)
In combination with read head CES-A-LMN-SC - between read headsmin. 20 mm
In combination with read head CES-A-LQA-SC - between read headsmin. 80 mm
Ordernumber113090
Масса0,334kg
Customs tariff number85364110
ECLASS 11.027-27-24-03 Safety-related transponder switch