EUCHNER GmbH + Co. KG CES-I-AP-U-C14-U20-158632
CES-I-AP-U-C14-U20-158632
Технические характеристики
| according to EN 60947-5-2 | 10 % |
|---|---|
| Напряжение питания | 0.25 ... 8 A |
| Напряжение питания | 30 V |
| Напряжение питания | 0.5 kV |
| U B | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
| Safety outputs | max. 300 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 260 ms |
| Safety class | III |
| Current consumption | max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Output type | Semiconductor output, p-switching, short circuit-proof |
| Напряжение питания | 0.8 x UB ... UB V DC |
| Switching current | max. 50 mA |
| Electrical connection values - Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| HIGH U (FO1A) / U (FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| LOW U (FO1A) / U (FO1B) | 0 ... 1 V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| rated conditional short-circuit current | 100 A |
| Discrepancy time | max. 10 ms |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| per safety output | 1 ... 150 mA |
| Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | min. 100 ms |
| Connection type | Connecting cable PUR, length 20 m |
| Fixing screws | 2 Nm |
| Ready delay | 10 s |
| Dynamic bending radius | 10 x cable diameter |
| Static bending radius | 5 x cable diameter |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| between switches | min. 80 mm |
| Mounting type | Surface mounting on metal |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| at U B = 24 V DC | 0 ... 65 °C |
| Housing | 2-component epoxy resin |
| in z direction / installation position A | 20 mm |
| in z direction / installation position D | 15 mm |
| in y direction / installation position D | 68 mm |
| in x/z direction / installation position D | 60 mm |
| in y direction / installation position A | 72 mm |
| in x/z direction / installation position A | 64 mm |
| In combination with actuator CES-A-BBN-C14-160441 - in z direction / installation position A | min. 10 mm |
| In combination with actuator CES-A-BBN-C14-160441 - in z direction / installation position D | min. 5 mm |
| Ordernumber | 158632 |
| Масса | 0,8kg |
| Customs tariff number | 85365019000 |
| ECLASS 11.0 | 27-27-24-03 Safety-related transponder switch |