EUCHNER GmbH + Co. KG CES-I-BP-M-C07-SB-160076
CES-I-BP-M-C07-SB-160076
Технические характеристики
| according to EN 60947-5-2 | 10 % |
|---|---|
| Напряжение питания | 0.25 ... 8 A |
| rated conditional short-circuit current | 100 A |
| Напряжение питания | 75 V |
| Напряжение питания | 1.5 kV |
| U B | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
| Safety outputs | max. 100 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 125 ms |
| Safety class | III |
| Current consumption | 40 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Output type | p-switching, short circuit-proof |
| Напряжение питания | UB-1.5 ... UB V DC |
| Switching current | 1 ... 50 mA |
| Electrical connection values - Output type | Semiconductor outputs, p-switching, short circuit-proof |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| Discrepancy time | max. 10 ms |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Electrical connection values - Switching current | 1 ... 150 mA |
| Test pulse duration | 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | ca 100 ms |
| Dimensions | 40 x 26.5 x 18 |
| Connection type | M12 plug connector, 5-pin |
| Tightening torque | max. 0.8 Nm |
| Ready delay | 5 s |
| Operating altitude | max. 4 000 m |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| between switches | min. 50 mm |
| Mounting type | Surface mounting on metal |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| at U B = 24 V DC | -25 ... 55 °C (65°C at IL = max. 10 mA per safety output) |
| Housing | Plastic, PBT-PC-GF30 |
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
| Additional feature | Caps included |
| Switching hysteresis | 1 ... 2 mm |
| Installation position A | 6.5 mm (on steel) |
| Installation position B | 5 mm (on steel) |
| in x direction/installation position A + B | max. 13 mm |
| in x direction/installation position A | min. 3 mm |
| in x direction/installation position B | min. 2 mm (only at an ambient temperature of 0°C ... 70°C) |
| In combination with actuator CES-A-BDN-06-158210 - Installation position A | 16 mm |
| Installation position C | 11 mm |
| In combination with actuator CES-A-BDN-06-158210 - in x direction/installation position A | 24 mm |
| in the z-direction / Installation position C | 21 mm |
| In combination with actuator CES-A-BDN-06-158210 - in the z-direction / Installation position C | min. 6 mm |
| Installation position A + B | 13 mm |
| Installation position C + D | 7 mm |
| In combination with actuator CES-A-BTN-C07-156230 - in x direction/installation position A + B | 20 mm |
| in x direction/installation position C + D | 17 mm |
| In combination with actuator CES-A-BTN-C07-156230 - in x direction/installation position B | min. 9 mm |
| in x direction/installation position D | min. 2 mm |
| In combination with actuator CES-A-BTN-C07-156230 - in x direction/installation position A | min. 10 mm |
| in x direction/installation position C | min. 3 mm |
| Ordernumber | 160076 |
| Масса | 0,05kg |
| Customs tariff number | 85365019000 |
| ECLASS 11.0 | 27-27-24-03 Safety-related transponder switch |