EUCHNER GmbH + Co. KG CMS-E-ER
CMS-E-ER
Технические характеристики
| LED display | 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2) |
|---|---|
| Напряжение питания | 0.75 A Automatically resetting fuse PTC |
| External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 4 A gG |
| Connection cross section | 0.14 ... 2.5 mm² |
| Напряжение питания | 250 V |
| AC/DC | -10% ... 24 ... +10% V (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) |
| AC-1 | 3A, 230V; 3A, 24V (Max. switching current per contact) |
| AC-15 | 0.9A , 240V and 0.9A , 24V (Max. switching current per contact) |
| DC-13 | 1.5A, 24V (Max. switching current per contact) |
| Risk time according to EN 60947-5-3 | max. 20 ms |
| According to UL class 2 | Input: 24 V AC/DC; output: 30 V AC, 24 V DC |
| Safety contacts 13/14, 23/24 | max. 720 VA |
| Electrical connection values - Safety contacts 13/14, 23/24 | max. AC 240 V |
| Auxiliary contacts 31/32 | max. 1500 mA at DC 24 V |
| at DC 24 V | 10 ... 110 mA |
| Degree of contamination (external, according to EN 60947-1) | 2 |
| Approach direction | Z (If the approach speed is low, the approach direction Z should be avoided.) |
| Connection type | Connection terminals |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 10 x 10⁶ |
| Mounting type | Mounting rail TH 35 (EN IEC 60715) |
| Degree of protection | Terminals IP20 / housing IP40 |
| Рабочая температура | 0 ... 55 °C |
| Housing | Polyamide PA6.6 |
| in compliance with | EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119:2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013 |
| Secured switch-off distance s ar | 14 mm (The assured release distance s_ar corresponds to the reset distance.) |
| with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - Secured switch-off distance s ar | 17 mm (The assured release distance s_ar corresponds to the reset distance.) |
| In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD - Secured switch-off distance s ar | 12 mm (The assured release distance s_ar corresponds to the reset distance.) |
| In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD - with center offset m=0 | min. 3 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD - at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - Secured switch-off distance s ar | 13 mm (The assured release distance s_ar corresponds to the reset distance.) |
| In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - Secured switch-off distance s ar | 31 mm (The assured release distance s_ar corresponds to the reset distance.) |
| In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - Secured switch-off distance s ar | 20 mm (The assured release distance s_ar corresponds to the reset distance.) |
| In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - with center offset m=0 | min. 10 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - at s = 3 mm read distance | 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| Ordernumber | 099182 |
| Масса | 0,225kg |
| Customs tariff number | 85364110 |
| ECLASS 11.0 | 27-27-24-02 Safety-related magnetic proximity switch |