CMS-E-FR

EUCHNER GmbH + Co. KG CMS-E-FR

CMS-E-FR

  • Бренд: EUCHNER GmbH + Co. KG
  • Артикул (MPN): CMS-E-FR
  • Статус производства: Не определён

Технические характеристики

LED display1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads
Напряжение питания0.75 A Automatically resetting fuse PTC
Safety contacts 13/14, 23/244 A gG (External contact fuse (safety circuit) acc. to EN IEC 60269-1)
Connection cross section0.14 ... 2.5 mm²
Напряжение питания250 V
AC/DC24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)
AC-13A, 230V ; 3A , 24V (Max. switching current per contact)
DC-131.5A, 24V (max. switching current)
AC-150.9 A 240 V and 0.9 A, 24 V (Max. switching current per contact)
Risk time according to EN 60947-5-3max. 20 ms
According to UL class 2Input: 24 V AC/DC; output: 30 V AC, 24 V DC
Electrical connection values - Safety contacts 13/14, 23/24max. 720 VA
Auxiliary contacts 31/32max. 1500 mA at DC 24 V
Semiconductor outputs 01 to 0650 mA at DC 24 V (per monitoring output 01 to 06 mA)
at U B = 24 V DC10 ... 120 mA
Degree of contamination (external, according to EN 60947-1)2
Approach directionZ (If the approach speed is low, the approach direction Z should be avoided.)
Connection typeConnection terminals
Storage temperature-25 ... 70 °C
Mechanical life10 x 10⁶
Mounting typeMounting rail TH 35 (EN IEC 60715)
Degree of protectionTerminals IP20 / housing IP40
Рабочая температура0 ... 55 °C
HousingPolyamide PA6.6
in compliance withEN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119: 2013; EN 6100-2-6: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013
Secured switch-off distance s ar12 mm (The assured release distance s_ar corresponds to the reset distance.)
with center offset m=0min. 3 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
at s =3 mm read distance2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - Secured switch-off distance s ar17 mm (The assured release distance s_ar corresponds to the reset distance.)
In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - with center offset m=0min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF - at s =3 mm read distance2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - Secured switch-off distance s ar31 mm (The assured release distance s_ar corresponds to the reset distance.)
In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - with center offset m=0min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC - at s =3 mm read distance2.5 mm 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - Secured switch-off distance s ar13 mm (The assured release distance s_ar corresponds to the reset distance.)
In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - with center offset m=0min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and actuator CMS-MH-BB - at s =3 mm read distance2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA - Secured switch-off distance s ar14 mm (The assured release distance s_ar corresponds to the reset distance.)
In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA - with center offset m=0min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA - at s =3 mm read distance2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - Secured switch-off distance s ar20 mm (The assured release distance s_ar corresponds to the reset distance.)
In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - with center offset m=0min. 10 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
In combination with read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and actuator CMS-MH-AA - at s =3 mm read distance2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
Ordernumber099258
Масса0,349kg
Customs tariff number85364110
ECLASS 11.027-27-24-02 Safety-related magnetic proximity switch
Получить предложение по этой позиции