EUCHNER GmbH + Co. KG CTM-L2-AS1B-U-AZ-SJ-163976
CTM-L2-AS1B-U-AZ-SJ-163976
Технические характеристики
| Repeat accuracy R | 10 % |
|---|---|
| ASI operating current | max. 50 mA |
| Напряжение питания | 20.4 ... 24 ... 26.4 V |
| Auxiliary current AS-Interface | 650 mA |
| AS-Interface protocol | ASi-3 |
| ASI data out | D0 = control of guard locking |
| ASI data in | D0, D1 = door position, D2, D3 = guard locking |
| AS-Interface slave type | ID-Code: B, EA-Code: 7 |
| Напряжение питания | 26.5 ... 30 ... 31.6 V |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Solenoid duty cycle | 100 % |
| Switching load | DC 24V, UL Class 2 (alternatively, see operating instructions) |
| Safety class | III |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Anfahrgeschwindigkeit | max. 20 m/min |
| Connection type | Plug connector M12, 4-pin |
| Extraction force | 18 N |
| Ready delay | 3 s |
| Actuating force | 20 N |
| Installation orientation | any |
| Switching frequency | max. 0.25 Hz |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 2 mm |
| Retention force | 5 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67 (In the inserted and screwed tight state) |
| at U B = 24 V DC | -20 ... 60 °C |
| Safety switch housing | Reinforced thermoplastic |
| Seals | Fluorinated rubber (FKM) |
| Locking force F max | 1300 N |
| Locking force F Zh | 1000 N |
| Guard locking principle | Open-circuit current principle |
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
| Ordernumber | 163976 |
| Масса | 0,26kg |
| Customs tariff number | 85365019000 |
| ECLASS 11.0 | 27-27-24-05 Safety-related transponder switch with guardlocking |