Технические характеристики
| Only for sliding door | 20 mm (Applies only to use on sliding doors with deactivated guard lock monitoring) |
|---|---|
| Ethernet | Ethernet/IP cable, at least cat. 5e |
| Напряжение питания | 75 V |
| Напряжение питания | 0.5 kV |
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
| X1, X2 | max. 4000 mA |
| Safety class | III |
| Current consumption | max. 500 mA |
| Transponder coding | Unicode |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| external | min. 1 A slow blow |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
| Electrical connection values - L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
| Electrical connection values - L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
| Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) |
| Mechanical values and environment - Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) |
| Installation orientation | Door hinge DIN right |
| Switching frequency | 0.25 Hz |
| Storage temperature | -25 ... 70 °C |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
| Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Emergency stop / machine stop | max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP54 |
| at U B = 24 V DC | -20 ... 55 °C |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
| Additional feature | incl. lens set, ID no. 120344 |
| Bus data protocol | Ethernet/IP |
| Safety data protocol | CIP Safety |
| Date interface | Ethernet |
| Ordernumber | 136553 |
| Масса | 0,kg |
| Global Trade Item Number (GTIN) | 4047048007031 |
| Customs tariff number | 85371098 |
| ECLASS 11.0 | 27-27-24-03 Safety-related transponder switch |