MGB-L0HB-EIA-R-158249

EUCHNER GmbH + Co. KG MGB-L0HB-EIA-R-158249

MGB-L0HB-EIA-R-158249

  • Бренд: EUCHNER GmbH + Co. KG
  • Артикул (MPN): MGB-L0HB-EIA-R-158249
  • Статус производства: Не определён

Технические характеристики

Installation orientationDoor hinge DIN right
Storage temperature-25 ... 70 °C
Degree of protectionIP65
Рабочая температура-20 ... 55 °C
HousingFiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Additional featurewith mounting plate and automatic lockout mechanism
Only for sliding door20 mm (Applies only to use on sliding doors with deactivated guard lock monitoring)
EthernetEthernet/IP cable, at least cat. 5e
Напряжение питания75 V
Напряжение питания0.5 kV
EMC protection requirementsIn accordance with EN 61000-4 and EN 61326-3-1
X1, X2max. 4000 mA
Safety classIII
Current consumptionmax. 500 mA
Transponder codingUnicode
Degree of contamination (external, according to EN 60947-1)3
externalmin. 1 A slow blow
L124 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
L224 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Electrical connection values - L124 V DC -15% ... +10% (For looping through for connected devices)
Electrical connection values - L224 V DC -15% ... +10% (For looping through for connected devices)
Ethernet/IP cable, at least cat. 5eM12, D-coded, screened (X3)
Mechanical values and environment - Ethernet/IP cable, at least cat. 5eM12, D-coded, screened (X4)
Mechanical values and environment - Installation orientationDoor hinge DIN right
Switching frequency0.25 Hz
Mechanical values and environment - Storage temperature-25 ... 70 °C
in case of use as door stop, and 1 Joule impact energy0.1 x 10⁶
Bolt positionmax. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door positionmax. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stopmax. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistanceAcc. to EN IEC 60947-5-3
Mechanical values and environment - Degree of protectionIP54
at U B = 24 V DC-20 ... 55 °C
Mechanical values and environment - HousingFiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Miscellaneous - Additional featureincl. lens set, ID no. 120344
Bus data protocolEthernet/IP
Safety data protocolCIP Safety
Date interfaceEthernet
Ordernumber158249
Масса5,73kg
Global Trade Item Number (GTIN)4047048007086
Customs tariff number85371098
ECLASS 11.027-27-24-03 Safety-related transponder switch
Получить предложение по этой позиции