Honeywell International Inc. CP-AF-K3
Honeywell BW™ Flex CP-AF-K3
Категории:
Технические характеристики
| Brand | BW; Honeywell BW |
|---|---|
| Масса | 189 gram |
| Масса | With Catalytic LEL: 189 g (6.7 oz) with Alligator Clip and 173 g (6.1 oz) with Klick Fast Stud gram; With IR LEL: 186 g (6.6 oz) with Alligator Clip and 170 g (6.0 oz) with Klick Fast Stud gram |
| Instrument Size | 108.2mm x 61.5mm x 43.2mm (4.29in x 2.44in x 1.7in) with Alligator Clip |
| Sub-Category | Multi-Gas; Multi-Gas Detector |
| Sensor Range | CL2: 20 ppm; CO-H: 1000 ppm; CO: 1000 ppm; COSH Dual Toxic CO: 1,000 ppm; COSH Dual Toxic H2S: 100 ppm; H2S: 200 ppm; HCN: 50 ppm; LEL-CB-F: 100% LEL; LEL-CB-UF: 100% LEL; LEL-IR: 100% LEL; NDIR-CO2: 5% VOL (50000 ppm); NO2: 20 ppm; NO: 100 ppm; O2: 25% VOL; SO2: 20 ppm |
| Humidity Range | 0%-95% RH percent; 5 to 95% RH (Non-Condensing) percent |
| Minimum Temperature | -40; -40 degree Celsius |
| Maximum Temperature | 60; 60 degree Celsius |
| Alarm Included | Yes |
| Series Name | Honeywell BW Flex 4/5 Series |
| Alarm Type | Audible (95 dB); Vibrating; Visual |
| Alarm Settings | Low, High, TWA, STEL, Negative Drift, OL (Over Limit), Multi-Alarm, Low Battery |
| Battery Run Time | 40 Days @8 Hours of Use/Day with NDIR CH4 Sensor hours; Up to 15 Hours with Catalytic LEL hours |
| Batteries Required | Yes |
| Batteries Included | Yes |
| Standards | ATEX, IEC Ex, CSA, FTZU, INMETRO, GOSST, CCCF, CPA, KRS, MED, DNV, SABS, FCCID, IC, UKCA, CE |
| Сертификация | ATEX, IECEX |
| Datalogging | 45 days of data at 15 sec interval, 8hrs/day |
| Features & Benefits | Advanced Connectivity: Using a Smart Mobile Device or PC Operators can Fully Configure their Device Using Safety Suite Solutions on iOS, Android or Windows Platforms; Easy to Use: The Single Pushbutton Operation, Intuitive User Interface, and Simple Green/ Amber/Red Alarm System Simplifies Training and Enables Users to be Up and Running Quickly; Reliable: Small, Lightweight, Rugged, and Weatherproof, The BW Flex can be Used in Potentiality Explosive Atmospheres. Indoor, Outdoor, Onshore or Offshore; Responsive: Offering Instantaneous Alarms, with Time Weighted Average Exposure Levels (STEL/TWA), Users are Protected All Round, From Flammable, Oxygen, and Toxic Gases in the Work Place; Status At Glance: The SafetyTick and IntelliFlash Status Indicators Enable Quick Visual Compliance Checks of Instrument Status in the Field. The Intuitive Green, Amber, and Red Color Coding Keep It Simple |
| Filter Type | Catalytic Bead Filtered |
| Filter Required | Yes |
| Filter Included | Yes |
| User Options | Always ON; Apply Enforcement Policies; Assign Worker and Location Assignments; Change High, Low, TWA and STEL Alarm Set Points; Latching Alarms; Peak Hold Function; Set Calibration and/or Bump Test Reminders |
| Sensor Type | Catalytic, IR |
| Number of Sensors Included | 4 |
| Warranty | 3 Years |
| Wireless Technology | BLE |
| Ingress Protection | IP66/68; IP66/IP68 |
| Gas Type | H2S, CO, O2, LEL, SO2 |
| External Calibration | IntelliDox Instrument Management System |
| Decibels | 95 decibel |
| Combustible Concentration | LEL-CB-F 100% LEL; LEL-CB-UF 100% LEL; LEL-IR 100% LEL |
| Combustible | Yes |
| Tests | Perform Diagnostic of Sensor, Circuitry on Activation; Reflex Test Automatically Performs Analog Sensor Diagnostic Every 10 Min |
| Status Indicator | Amber: Warning; Green: Good to Go; Red: Stop |
| Sensor Life | 1 to 2 Years: HCN, CL2; 2+ Years: COSH Dual Toxic H2S, COSH Dual Toxic CO, CO-H, NO, NO2; 3 to 5+ Years: LEL-IR, NDIR-CO2, LEL-CB-F, LEL-CB-UF, O2, H2S |
| Keypad Type | Single Push Button |
| Gases Detected | LEL-IR, NDIR-CO2, LEL-CB-F, LEL-CB-UF, O2, H2S, CO, CO-H, SO2, NO, NO2, HCN, CL2, COSH Dual Toxic H2S, COSH Dual Toxic CO |
| Connected Worker | Bluetooth (BLE) - Ability to Connect to Honeywell’S Safety Communicator App; Device Configurator App and Safety Suite Device Configurator Software |
| Size | 4.29 in × 2.44 in × 1.49 in (with Klick Fast Stud); 4.29 in × 2.44 in × 1.7 in (with Alligator Clip) |
| Power Source | Battery |
| Application | Confined Spaces or General Workers on a Plant; Potentially Explosive Atmospheres Found in Industrial, Marine and Mining Applications |
| Industry | Energy |
| description | EXTERNAL FILTER,BW Flex |