ifm electronic gmbh AC2750
AS-Interface PCB module, PCB 4DI 4DO T W A/B
Категории:
Технические характеристики
| Design | Only for operation with AS-i masters with the profile M4 |
|---|---|
| Application | For integration of mechanical switches into AS-i networks |
| Напряжение питания | 18...31.6 DC |
| Max. current consumption from AS-i [mA] | 180; (without sensors: < 30 mA; inputs and outputs active: < 180 mA) |
| Protection class | III |
| Max. current load total [A] | 0.15; (total current for all inputs and outputs supplied from AS-i: 150 mA) |
| Integrated watchdog | yes |
| Number of inputs and outputs | Number of digital inputs: 4; Number of digital outputs: 4 |
| Number of digital inputs | 4 |
| Input circuit of digital inputs | PNP |
| Sensor supply of the inputs | AS-i |
| Напряжение питания | 18...30; (DC) |
| Max. total current rating of inputs [mA] | 150 |
| Input current High [mA] | 6...10 |
| Input current low [mA] | 0...2 |
| Switching level high [V] | > 11 |
| Digital inputs protected against short circuits | yes |
| Electrical design | PNP |
| Number of digital outputs | 4 |
| Circuit | PNP |
| Напряжение питания | 18...30; (DC) |
| Max. current load per output [mA] | 100; (utilization category DC-13 (control of electromagnets): 2,5 W (IEC 60947-5-1)) |
| Max. current load outputs total [A] | 0.15 |
| Short-circuit proof | yes |
| Electrically separated | yes |
| Actuator supply outputs | AS-i |
| Рабочая температура | -25...55 |
| Protection | IP 20 |
| EMC | EN 50295 |
| AS-i version | 3.0 |
| Extended addressing mode | yes |
| AS-i master profile | M4 |
| AS-i profile | S-7.A.7 |
| AS-i I/O configuration [hex] | 7 |
| AS-i ID code [hex] | A.7 |
| Сертификация | 102301 |
| Масса | 75.5 |
| Housing | rectangular |
| Type of mounting | Installation in a surface-mounted housing |
| Dimensions [mm] | 76.3 x 31.1 x 12 |
| Материал | housing: PC potted |
| Display | Power: LED, green; errors: LED, red; Function: LED, yellow |
| Remarks | A watchdog function switches the outputs off if there is no communication on the AS-i line.; Install the unit so that exposed parts cannot be touched.; Installation in a surface-mounted housing with the dimensions of 68 x 136 x 53 mm (LxWxH), e.g. Schneider Electric Harmony XALD03, XALD04; Do not connect any of the following points to an external potential:; 0-, I+, I1, I2, I3, I4; The connections are electrically connected with the AS-i cable.; Can be used up to a height of 2000 metres above sea level |
| Pack quantity | 1 pcs. |
| Cable | 0.2 m, PVC |