ifm electronic gmbh CP100S
safety package for ecomatBasic and ecomatController, Controller safety package
Технические характеристики
| Application | for functionally safe applications with the ecomatBasic and the ecomatController |
|---|---|
| Function | software package for programming in CODESYS 3.5 SP18 |
| Software | CP100S |
| Hardware | CR403S, CR413S; CR710S, CR711S; CR720S, CR721S |
| Input function | safety inputs: 64; Connection: IN00xx, IN01xx, IN02xx, IN03xx, IN04xx, IN05xx, IN06xx, IN07xx, IN08xx, IN09xx, IN10xx, IN11xx, IN12xx, IN13xx, IN14xx, IN15xx, IN16xx, IN17xx, IN18xx |
| Output function | safety outputs: 68; Connection: OUT00xx, OUT01xx, OUT02xx, OUT03xx, OUT04xx, OUT05xx |
| Protocol | CANopen Safety; SAE J1939-76 |
| EMC | DIN EN 61326-3-1 |
| Complies with the requirements | IEC 61508 SIL 2; ISO 26262 ASIL C |
| MIssion time TM | 20 years |
| PFH [1/h] | external one-channel input: 4.0E-09; external two-channel input: 5.0E-10; logic: 1,0E-07; external one-channel output: 2.0E-08; external two-channel output: 1.0E-09 |
| Total Life Time | 20 Jahre |
| TTrip | 10 h |
| Typical use case | PMFH: 48 Fit: this classification applies to the following assumption:; TLifetime (Total Operating Hours ) = 40000 h; (operating and non-operating phase of the device considered); (this is equivalent to operation for 20 years, 8 h a day on 250 days of the year or 10 h a day on 200 days) |
| Worst case | PMFH: 73 Fit: this classification applies to the following assumption:; "always on"; (non-operating phase of the device not considered) |
| Remarks | can be used in applications up to SIL 2 in accordance with IEC 62061; can be used in applications up to PL d in accordance with ISO 13849-1; can be used in applications up to AgPL d in accordance with ISO 25119; can be used in applications in accordance with DIN EN ISO 13766-2 |