CR710S

ifm electronic gmbh CR710S

Programmable controller for mobile machines, ecomatController/37

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): CR710S
  • Статус производства: Не определён

Технические характеристики

Total number of inputs20
Total number of outputs17
Communication interfaceEthernet; CAN; RS232
ProtectionIP 65; IP 67; (for inserted connectors with individually sealed cores and inserted M12 connectors or sealing caps: IP 67)
Напряжение питания8...32 DC; (VBB15, VBB30 voltage monitoring)
Напряжение питания12 / 24
Power consumption [W]12; (VBB30)
Reverse polarity protectionyes; (in case of supply via the on-board system / battery)
Total number of inputs and outputs37
Number of frequency inputs8
Number of resistor inputs4
Number of digital inputs20
Number of analog inputs16
Number1
Plug ST AOUT3001
Frequency inputfunction type: phase; software mode: IN_PHASE_CSO; IN_PHASE_CSI; input pair ST A: A: IN0000 + B: IN0001; A: IN0002 + B: IN0003; A: IN0500 + B: IN0501; A: IN0502 + B: IN0503; input range [V]: 0...32; Frequency [Hz]: 0,0625...5000; Switching level high [V]: > 70 % VBB30; Switching level low [V]: < 30 % VBB30; input resistance [Ω]: 10000; Accuracy: ± 10 µs
Analog inputfunction type: Voltage, ratiometric; software mode: IN_VOLTAGE_RATIO; input range [V]: 0...1000 ‰ VBB30; input resistance [Ω]: 51000; Resolution: 12 Bit; Accuracy: ± 320 mV; input frequency [Hz]: < 330; diagnostic level low: 0 ‰; (configurable); diagnostic level high: 1000 ‰; (configurable)
Digital inputSwitching level high [V]: > 70 % VBB30; Switching level low [V]: < 30 % VBB30; Accuracy: ± 5 % FS
Resistor inputfunction type: binary, high-side; software mode: IN_RESISTOR; input range [Ω]: 16...30000; measuring current [mA]: < 2,0; Resolution: 12 Bit; Accuracy: 16...3000 Ω: ± 60 Ω; 3000...15000 Ω: ± 750 Ω; 15000...30000 Ω: ± 3000 Ω; diagnostic level low: 0 Ω; (configurable); diagnostic level high: 30000 Ω; (configurable)
Number of digital outputs16
Number of analog outputs1
Number of PWM outputs16
Number of PWM-I outputs10
Number of outputs with H-bridge2
Output group switchfunction type: second independent switch-off mode of the output group; software mode: OUT_DIGITAL_VIRT; Voltage range [V]: 6...32 DC; voltage measurement [V]: 0...36; voltage measurement accuracy [mV]: ± 360; Current rating [A]: 12; accuracy of the current measurement [mA]: ± 600; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 12000; (configurable)
PWM outputfunction type: binary, high-side; software mode: OUT_PWM_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; output frequency [Hz]: 20...2000; pulse/pause ratio: 1...1000 ‰; (configurable); Resolution: 1 ‰; (20...250 Hz); Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 125; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
PWM-I outputfunction type: current-controlled; software mode: OUT_CURRENT_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; output frequency [Hz]: 20...2000; control range [A]: 0,05...2,5; setting resolution [mA]: 1; control resolution [mA]: 2; Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 37,5; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Digital outputfunction type: binary, high-side; software mode: OUT_DIGITAL_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 125; switching status monitoring [V]: 2; switching status monitoring accuracy [V]: ± 1; Diagnostic function: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Sensor supplyfunction type: voltage supply; software mode: OUT_SENSOR_10; Output voltage [V]: 10; Accuracy [mV]: ± 600; min. load current [mA]: 10; max. load current [mA]: 200; current measurement A: 0...2,5; accuracy of the current measurement [mA]: ± 125; voltage measurement [V]: 0...10; voltage measurement accuracy [mV]: ± 500; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Analog outputfunction type: Voltage; software mode: OUT_ANALOG_10; Voltage range [V]: 0...10 DC; Accuracy [mV]: ± 500; Current rating [mA]: 5; step response time [ms]: < 1,8 (10...90 %); voltage measurement [V]: 0...10; voltage measurement accuracy [mV]: ± 500
Parameter setting optionsCODESYS 3.5
PLC function to IEC 61131-3yes
Operating systemreal-time operating system
Number of CAN interfaces4
Number of Ethernet interfaces2
Number of R232 interfaces1
Transmission rate9,6...115,2 kBit/s
ProtocolTCP/IP; UDP/IP; Modbus TCP
InterfaceCAN Interface 2.0 A/B ISO 11898
Transmission standard10Base-T; 100Base-TX
Note on interfaces2 ports with integrated switch
Housing temperature [°C]-40...85
Storage temperature [°C]-40...85
Max. relative air humidity [%]90; (non condensing)
Max. height above sea level [m]3000
Pollution degree2
Chemical mediaISO 16750-5: AA, BB, BD, CC, DB, DC, DD, ED; only one chemical permitted at a time
EMCUN/ECE-R10 Noise emission and noise interference:: 100 V/m; DIN EN 61000-6-2: noise immunity; DIN EN 61000-6-4: noise emission; ISO 7637-2 pulse 1: severity level 4 / function state C (24 V); ISO 7637-2 pulse 2a: severity level 4 / function state A (24 V); ISO 7637-2 pulse 2b: severity level 4 / function state C (24 V); ISO 7637-2 pulse 3a: severity level 4 / function state A (24 V); ISO 7637-2 pulse 3b: severity level 4 / function state A (24 V); ISO 7637-2 pulse 4: severity level 4 / function state A (24 V); ISO 7637-2 pulse 5: severity level 3 / function state A (24 V); ISO 7637-2 pulse 4: severity level 4 / function state A (12 V); EN 45545-2; EN 50121-3-2
Continuous shock resistanceISO 16750-3: 30 g 6 ms / 24000 shocks
Vibration resistanceISO 16750-3 Test VII: random, mounting place car body; EN 60068-2-6 sine: 10...500 Hz / 10 cycles/axis, sine
Climatic testsEN 60068-2-30 damp heat: cyclical: 55 °C upper temperature limit / 6 cycles; EN 60068-2-78 damp heat: constant: 40 °C 93 % rH / test period 21 days
Salt spray testEN 60068-2-52 Salt spray: severity level 3 / motor vehicle
Electrical safetyIEC 61010-1: safety requirements: general requirements; IEC 61010-2-201: safety requirements: particular requirements for control equipment
Complies with the requirementsISO 13849-1 PL d; IEC 61508 SIL 2; IEC 62061 SIL 2; ISO 25119 AgPLd; ISO 26262 ASIL C
MIssion time TM20 years
PFH [1/h]external one-channel input: 4.0E-09; external two-channel input: 5.0E-10; logic: 1,0E-07; external one-channel output: 2.0E-08; external two-channel output: 1.0E-09
Total Life Time20 years
TTrip10 h
Typical use casePMFH: 48 Fit: this classification applies to the following assumption:; TLifetime (Total Operating Hours ) = 40000 h; (operating and non-operating phase of the device considered); (this is equivalent to operation for 20 years, 8 h a day on 250 days of the year or 10 h a day on 200 days)
Worst casePMFH: 73 Fit: this classification applies to the following assumption:; "always on"; (non-operating phase of the device not considered)
Масса1546.3
Housingrectangular
Type of mountingscrew mounting; (4 x M6)
Dimensions [mm]219 x 203 x 47
Материалhousing: diecast aluminium powder-coated
Displayconnection: LED, green lights; Data transmission: LED, green flashing
Processor32-Bit Triple-Core
Working memory2,7 MByte RAM
Mass storage9 MByte Flash
Non-volatile memory10 kByte
Boot time< 3 s
Items suppliedProtective cap: M12; self-tapping screw: 1 x M4, for shield connection
Remarksthe maximum height above sea level is 5000 m in case of supply via the battery / on-board system; can be used in applications up to SIL 2 in accordance with IEC 62061; can be used in applications up to PL d in accordance with ISO 13849-1; can be used in applications up to AgPL d in accordance with ISO 25119; can be used in applications in accordance with DIN EN ISO 13766-2
Pack quantity1 pcs.
Connector1 x AMP
Получить предложение по этой позиции