CR720S

ifm electronic gmbh CR720S

Programmable controller for mobile machines, ecomatController/98

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): CR720S
  • Статус производства: Не определён

Технические характеристики

Total number of inputs60
Total number of outputs39
Communication interfaceEthernet; CAN; RS232
ProtectionIP 65; IP 67; (for inserted connectors with individually sealed cores and inserted M12 connectors or sealing caps: IP 67)
Напряжение питания8...32 DC; (VBB15, VBB30 voltage monitoring)
Напряжение питания12 / 24
Power consumption [W]12; (VBB30)
Reverse polarity protectionyes; (in case of supply via the on-board system / battery)
Total number of inputs and outputs89
Number of frequency inputs16
Number of resistor inputs4
Number of digital inputs60
Number of analog inputs40
Number2
Plug ST AOUT3001
Plug ST BOUT3002
Frequency inputfunction type: phase; software mode: IN_PHASE_CSO; IN_PHASE_CSI; input pair ST A: A: IN0000 + B: IN0001; A: IN0002 + B: IN0003; A: IN0500 + B: IN0501; A: IN0502 + B: IN0503; input pair ST B: A: IN1000 + B: IN1001; A: IN1002 + B: IN1003; A: IN1500 + B: IN1501; A: IN1502 + B: IN1503; input range [V]: 0...32; Frequency [Hz]: 0,0625...5000; Switching level high [V]: > 70 % VBB30; Switching level low [V]: < 30 % VBB30; input resistance [Ω]: 10000; Accuracy: ± 10 µs
Analog inputfunction type: Voltage, ratiometric; software mode: IN_VOLTAGE_RATIO; input range [V]: 0...1000 ‰ VBB30; input resistance [Ω]: 51000; Resolution: 12 Bit; Accuracy: ± 320 mV; input frequency [Hz]: < 330; diagnostic level low: 0 ‰; (configurable); diagnostic level high: 1000 ‰; (configurable)
Digital inputSwitching level high [V]: > 70 % VBB30; Switching level low [V]: < 30 % VBB30; Accuracy: ± 5 % FS
Resistor inputfunction type: binary, high-side; software mode: IN_RESISTOR; input range [Ω]: 16...30000; measuring current [mA]: < 2,0; Resolution: 12 Bit; Accuracy: 16...3000 Ω: ± 60 Ω; 3000...15000 Ω: ± 750 Ω; 15000...30000 Ω: ± 3000 Ω; diagnostic level low: 0 Ω; (configurable); diagnostic level high: 30000 Ω; (configurable)
Number of digital outputs36
Number of analog outputs2
Number of PWM outputs36
Number of PWM-I outputs24
Number of outputs with H-bridge4
Output group switchfunction type: second independent switch-off mode of the output group; software mode: OUT_DIGITAL_VIRT; Voltage range [V]: 6...32 DC; voltage measurement [V]: 0...36; voltage measurement accuracy [mV]: ± 360; Current rating [A]: 12; accuracy of the current measurement [mA]: ± 600; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 12000; (configurable)
PWM outputfunction type: binary, high-side; software mode: OUT_PWM_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; output frequency [Hz]: 20...2000; pulse/pause ratio: 1...1000 ‰; (configurable); Resolution: 1 ‰; (20...250 Hz); Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 125; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
PWM-I outputfunction type: current-controlled; software mode: OUT_CURRENT_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; output frequency [Hz]: 20...2000; control range [A]: 0,05...2,5; setting resolution [mA]: 1; control resolution [mA]: 2; Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 37,5; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Digital outputfunction type: binary, high-side; software mode: OUT_DIGITAL_CSO; Voltage range [V]: 6...32 DC; switching current [A]: 0,025...2,5; Min. load resistance [Ω]: 12 V: 4,8 Ω / 24 V: 9,6 Ω; protective circuitry: inductive load; thermal protection; current measurement [A]: 0...4; accuracy of the current measurement [mA]: ± 125; switching status monitoring [V]: 2; switching status monitoring accuracy [V]: ± 1; Diagnostic function: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Sensor supplyfunction type: voltage supply; software mode: OUT_SENSOR_10; Output voltage [V]: 10; Accuracy [mV]: ± 600; min. load current [mA]: 10; max. load current [mA]: 200; current measurement A: 0...2,5; accuracy of the current measurement [mA]: ± 125; voltage measurement [V]: 0...10; voltage measurement accuracy [mV]: ± 500; Diagnostic functions: wire break; short circuit; current monitoring; lower limit of current monitoring [mA]: 0; (configurable); upper limit of current monitoring [mA]: 2500; (configurable)
Analog outputfunction type: Voltage; software mode: OUT_ANALOG_10; Voltage range [V]: 0...10 DC; Accuracy [mV]: ± 500; Current rating [mA]: 5; step response time [ms]: < 1,8 (10...90 %); voltage measurement [V]: 0...10; voltage measurement accuracy [mV]: ± 500
Parameter setting optionsCODESYS 3.5
PLC function to IEC 61131-3yes
Operating systemreal-time operating system
Number of CAN interfaces4
Number of Ethernet interfaces2
Number of R232 interfaces1
Transmission rate9,6...115,2 kBit/s
ProtocolTCP/IP; UDP/IP; Modbus TCP
InterfaceCAN Interface 2.0 A/B ISO 11898
Transmission standard10Base-T; 100Base-TX
Note on interfaces2 ports with integrated switch
Housing temperature [°C]-40...85
Storage temperature [°C]-40...85
Max. relative air humidity [%]90; (non condensing)
Max. height above sea level [m]3000
Pollution degree2
Chemical mediaISO 16750-5: AA, BB, BD, CC, DB, DC, DD, ED; only one chemical permitted at a time
EMCUN/ECE-R10 Noise emission and noise interference:: 100 V/m; DIN EN 61000-6-2: noise immunity; DIN EN 61000-6-4: noise emission; ISO 7637-2 pulse 1: severity level 4 / function state C (24 V); ISO 7637-2 pulse 2a: severity level 4 / function state A (24 V); ISO 7637-2 pulse 2b: severity level 4 / function state C (24 V); ISO 7637-2 pulse 3a: severity level 4 / function state A (24 V); ISO 7637-2 pulse 3b: severity level 4 / function state A (24 V); ISO 7637-2 pulse 4: severity level 4 / function state A (24 V); ISO 7637-2 pulse 5: severity level 3 / function state A (24 V); ISO 7637-2 pulse 4: severity level 4 / function state A (12 V); EN 45545-2; EN 50121-3-2
Continuous shock resistanceISO 16750-3: 30 g 6 ms / 24000 shocks
Vibration resistanceISO 16750-3 Test VII: random, mounting place car body; EN 60068-2-6 sine: 10...500 Hz / 10 cycles/axis, sine
Climatic testsEN 60068-2-30 damp heat: cyclical: 55 °C upper temperature limit / 6 cycles; EN 60068-2-78 damp heat: constant: 40 °C 93 % rH / test period 21 days
Salt spray testEN 60068-2-52 Salt spray: severity level 3 / motor vehicle
Electrical safetyIEC 61010-1: safety requirements: general requirements; IEC 61010-2-201: safety requirements: particular requirements for control equipment
Complies with the requirementsISO 13849-1 PL d; IEC 61508 SIL 2; IEC 62061 SIL 2; ISO 25119 AgPLd; ISO 26262 ASIL C
MIssion time TM20 years
PFH [1/h]external one-channel input: 4.0E-09; external two-channel input: 5.0E-10; logic: 1,0E-07; external one-channel output: 2.0E-08; external two-channel output: 1.0E-09
Total Life Time20 years
TTrip10 h
Typical use casePMFH: 48 Fit: this classification applies to the following assumption:; TLifetime (Total Operating Hours ) = 40000 h; (operating and non-operating phase of the device considered); (this is equivalent to operation for 20 years, 8 h a day on 250 days of the year or 10 h a day on 200 days)
Worst casePMFH: 73 Fit: this classification applies to the following assumption:; "always on"; (non-operating phase of the device not considered)
Масса1989.8
Housingrectangular
Type of mountingscrew mounting; (4 x M6)
Dimensions [mm]219 x 271 x 47
Материалhousing: diecast aluminium powder-coated
Displayconnection: LED, green lights; Data transmission: LED, green flashing
Processor32-Bit Triple-Core
Working memory2,7 MByte RAM
Mass storage9 MByte Flash
Non-volatile memory10 kByte
Boot time< 3 s
Items suppliedProtective cap: M12; self-tapping screw: 1 x M4, for shield connection
Remarksthe maximum height above sea level is 5000 m in case of supply via the battery / on-board system; can be used in applications up to SIL 2 in accordance with IEC 62061; can be used in applications up to PL d in accordance with ISO 13849-1; can be used in applications up to AgPL d in accordance with ISO 25119; can be used in applications in accordance with DIN EN ISO 13766-2
Pack quantity1 pcs.
Connector1 x AMP
Получить предложение по этой позиции