ifm electronic gmbh DD3003
evaluation unit for monitoring and converting frequency signals, MONITOR/SPEED/IOL/AC/DC
Технические характеристики
| Communication interface | IO-Link |
|---|---|
| Housing | rectangular |
| Dimensions [mm] | 126 x 50 x 112.4 |
| Design | housing for DIN rail mounting |
| Application | pulse evaluation system for frequency, rotational speed, speed, cycles and machine cycles |
| Напряжение питания | 110...240 AC / 18...30 DC; (tolerance AC operation: -20 % / +10 % ; DC operation: to SELV/PELV) |
| Напряжение питания | 110...240 |
| Напряжение питания | 24 |
| Nominal frequency AC [Hz] | 50...60 |
| Current consumption [mA] | AC operation: max. 8 A (including maximum AC supply for additional devices ) |
| Max. power consumption DC [W] | 9 |
| Напряжение питания | II |
| Auxiliary energy for sensors DC [V] | 16.5...27.7; (Short-circuit proof ; ≤ 200 mA) |
| Number of inputs and outputs | Number of digital inputs: 3; Number of digital outputs: 2; Number of relay outputs: 2 |
| Number of digital inputs | 3; (1 x Frequency 1 x Reset 1 x Restart) |
| Input circuit of digital inputs | PNP; (type 3 (IEC 61131-2)) |
| Input current High [mA] | 2...4 |
| Input current low [mA] | 0...1.5 |
| Switching level high [V] | 11...28 |
| Switching level low [V] | 0...5 |
| Number of digital outputs | 2 |
| Number of relay outputs | 2; (changeover contact) |
| Circuit | PNP |
| Max. current load per output [mA] | 10 |
| Short-circuit proof | no |
| Electrically separated | yes |
| Minimum load current [mA] | 10; (> 12 V) |
| Contact rating | 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating ; B300: 6000 cycles) |
| Switching frequency AC [Hz] | < 0.1 |
| Switching frequency DC [Hz] | < 0.1 |
| Setting range Hz [Hz] | 0.01...10000 |
| Measuring range [U/min] | 0...600000 |
| Measuring range [Hz] | 0...10000 |
| Accuracy | ± 0.2 Hz; (0.1...200 Hz); ± 0.1 % (of the measured value 200...10000 Hz)) |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 4.2.1: Measuring and Switching Sensor, high resolution, 1 channel; Common - I&D: Identification and Diagnosis; Extension: Sensor control; Extension: Quantity detection, switches when value exceeds the setpoint; Function: Locator; Function: ProductURI |
| Required master port class | A |
| Min. process cycle time [ms] | 4.3 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1833 |
| Рабочая температура | -40...60 |
| Рабочая температура | 2000...3000 m: max. 58 °C; 3000...4000 m: max. 56 °C; Contact rating Relay output: B300 max. 50 °C |
| Storage temperature [°C] | -40...85 |
| Max. relative air humidity [%] | 80; (31 °C; linearly decreasing to 50 % (40 °C)) |
| Max. height above sea level [m] | 4000 |
| Protection | IP 20; (when mounted) |
| Protection rating terminals | IP 20 |
| Pollution degree | 2 |
| EMC | EN 61000-6-2; EN 61000-6-8 |
| Electrical safety | EN 61010-1; EN 61010-2-201 |
| Масса | 321.5 |
| Type of mounting | Mounting on DIN rail; (TH35 (EN 60715)) |
| Материал | housing: plastics |
| Display | 1 x OLED display, 128 x 64 pixels luminous; Switching status: 2 x LED, yellow; Power: 1 x LED, red/green |
| Items supplied | cage clamps: 7 |
| Remarks | For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
| cage clamps | ...2.5 mm² |