ifm electronic gmbh DP3222
Converter 0...10 V - IO-Link, CONV 2x0-10V/IO-LINK/IP69K
Технические характеристики
| Number of inputs and outputs | Number of analog inputs: 2 |
|---|---|
| Communication interface | IO-Link |
| Application | converter from analog voltage signals to IO-Link; for connecting analog sensors to an IO-Link system; for use in wet environments; indoor use |
| Напряжение питания | 18...30 DC; ((in wet environments: 18...28 V) to SELV/PELV) |
| Напряжение питания | 24 |
| Current consumption [mA] | 300 |
| Max. total current rating of inputs [mA] | 200 |
| Number of analog inputs | 2 |
| Напряжение питания | 0...10 |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D: Identification and Diagnosis; Function: Multiple switching signal; Function: Adjustable switching signal |
| SIO mode | no |
| Required master port class | A/B |
| Process data analog | 2 |
| Min. process cycle time [ms] | 4.6 |
| Supported DeviceIDs | Type of operation: DeviceID; STATUS_B / CMPT = 2 (Factory setting): 1428 |
| Рабочая температура | -25...70 |
| Рабочая температура | 2000 m: -25...70 °C; 3000 m: -25...64 °C; 4000 m: -25...62 °C |
| Storage temperature [°C] | -25...70 |
| Max. relative air humidity [%] | 90; (linearly decreasing to 50 % (40 °C) non condensing) |
| Max. height above sea level [m] | 4000 |
| Protection | IP 67; IP 69K |
| Pollution degree | 2 |
| Chemical media | DIN EN ISO 175, Ecolab test method 40-1; the following media were tested for 28 days at constant room temperature using the dipping test method: P3-topax 66; P3-topax 990; Topactive 200; Topactive 500; Topactive OKTO |
| MTTF [years] | 504 |
| UL approval | Ta: max. 55 °C; File number UL: E205959 |
| Масса | 78.6 |
| Масса | 27 |
| Housing | rectangular |
| Dimensions [mm] | 63 x 30 x 24.5 |
| Материал | housing: PA |
| Материал | stainless steel (1.4404 / 316L) |
| Материал | FKM |
| Display | Power: 1 x LED, green; analog input: 2 x LED, yellow |
| Remarks | Further information is available in the manual.; the device complies with overvoltage category II |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12, straight; coding: A; Contacts: 4; Locking: stainless steel (1.4404 / 316L) |