ifm electronic gmbh GF854S
Fail-safe inductive sensor, GIFK4004-2PO/SIL2/US
Категории:
Технические характеристики
| Electrical design | PNP |
|---|---|
| Output function | 2 x OSSD (A1 and A2) |
| Enable zone [mm] | > 6 |
| Housing | Threaded type |
| Dimensions [mm] | M12 x 1 / L = 60 |
| Special feature | gold-plated contacts |
| Type of operation | permanent operation |
| Safety-related sub-function | safe state when damped correctly |
| Application | Use in mobile and harsh applications |
| Напряжение питания | 8...32 DC |
| Напряжение питания | 60 |
| Current consumption [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 1000 |
| Напряжение питания | 2.5; (30 mA) |
| Minimum load current [mA] | 1 |
| Permanent current rating of switching output DC [mA] | 50 |
| Switching frequency DC [Hz] | 10 |
| Output data | Interface type C class 1 |
| Напряжение питания | compatible with EN 61131-2 inputs type 1, 2 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Max. capacitive load CL_max [nF] | 20 |
| Safe switch-off distance s(ao) [mm] | < 3 |
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr] | 1...10 |
| Время отклика | 5 |
| Время отклика | 5 |
| Время отклика | 100 |
| Рабочая температура | -40...85 |
| Max. relative air humidity [%] | 50; (70 °C; <70 °C: >50 %) |
| Max. height above sea level [m] | 5000 |
| Ionizing radiation | not permissible |
| Protection | IP 65; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on) |
| Chemical media | test according to ISO 16750-5; the following media were tested for 22 hours at 60 °C: Coolants; (HoughtonHocut4480; Oemeta; HYCUT ET 46); The following media were tested for 22 hours at 75 °C: hydraulic fluids; (Fuchs Renoling B15 VG 46 HLP; Total BiohydranTMP 4HEES; Fuchs Hydrotherm 46 M HFC); transmission oils; (Fuchs TITAN ATF 3353 Dexron III); diesel; biodiesel; urea; (AdBlue); brake fluid; (K2 TURBO DOT 4); the following media were tested for 22 hours at 23 °C: corrosion protection; (Sonax special preservation wax ); cold cleaner; (Sonax cold cleaner S ); ammonia-based cleaner; (Weco Dr. Webers Salmiak-Konzentrat (concentrated ammonium chloride) ); battery acid; the following media were tested for 2 hours at 23 °C: wheel rim cleaner; (Sonax Xtreme Plus); the following media were tested for 10 minutes at 23 °C: premium-grade petrol lead-free |
| EMC | industrial environments; EN 60947-5-3; EN 61000-4-2 ESD: 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 20 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-5 Surge: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 61000-4-8: 30 A/m 50/60 Hz / 1000 A/m 0 Hz; EN 55011: class B; Mobile applications: only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems; ISO 10605 ESD: 8 kV CD / 15 kV AD; ISO 11452-2, ISO 11452-5 radiated immunity: 100 V/m; ISO 7637-2, ISO 16750-2 conducted immunity: 12 V / 24 V; pulse: 1 2a 3a 3b 4 5b; Severity level: III III III III III III 58V; Failure criterion: B B B A A C/B A; EN 55025 |
| Vibration resistance | EN 60068-2-6 Fc: 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
| Broadband noise | EN 60068-2-64 h: 5,9 g (10...2000 Hz) / effective acceleration for chassis mounting |
| Shock resistance | EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Ea: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature changes | EN 60068-2-14 Na: TA = -40°C; TB = 85°C; t1 = 30 min; t2 = 10 s 100 cycles |
| Salt spray test | EN 60068-2-52 Kb: severity level 5 (4 test cycles) |
| Complies with the requirements | ISO 13849-1: 2015 Category 2, PL d; IEC 61508 SIL 2; IEC 62061 SIL 2 |
| MIssion time TM [h] | ≤ 87600 |
| Mission time TM (additional indication) | industrial environments Temperature range -25...70 °C ≤ 175200 |
| PFH [1/h] | < 5E-08 |
| Масса | 86.8 |
| Mounting | non-flush mountable |
| Thread designation | M12 x 1 |
| Материал | threaded sleeve: brass white bronze coated; sensing face: LCP; LED window: PEI; lock nuts: brass white bronze coated |
| Tightening torque [Nm] | < 7 |
| Display | Display switching status: 4 LED, yellow |
| Items supplied | lock nuts: 2 |
| Remarks | material for secure mounting not supplied; fixing must be done by the user; meets the environmental and EMC requirements for operation in agricultural and forestry machinery, earthworks and construction machines as well as in industrial trucks; When used in industrial trucks, the screen of the connection cable has to be connected to the sensor.; Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37-2K) 12x12x1 mm |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |