ifm electronic gmbh GG714S
Fail-safe inductive sensor, GIGA4008-2PS/SIL2/V4A/US
Категории:
Технические характеристики
| Electrical design | PNP |
|---|---|
| Output function | 2 x OSSD (A1 and A2) |
| Enable zone [mm] | 0...6.5 |
| Housing | Threaded type |
| Dimensions [mm] | M18 x 1 / L = 71.5 |
| Special feature | gold-plated contacts |
| Type of operation | continuous operation (maintenance-free) |
| Safety-related sub-function | safe state when properly undamped |
| Application | Industrial applications |
| Напряжение питания | 19.2...30 DC |
| Напряжение питания | 30 |
| Current consumption [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 1000 |
| Напряжение питания | 2.5; (30 mA) |
| Permanent current rating of switching output DC [mA] | 100 |
| Output data | Interface type C class 1 |
| Напряжение питания | compatible with EN 61131-2 inputs type 1, 2 |
| Short-circuit protection | yes |
| Overload protection | no |
| Max. capacitive load CL_max [nF] | 20 |
| Safe switching-off distance s(ar) [mm] | 11 |
| Время отклика | 1 |
| Время отклика | 1 |
| Время отклика | 20 |
| Рабочая температура | -40...70 |
| Rate of temperature change [K/min] | 0.5 |
| Max. relative air humidity [%] | briefly: 5...95 %; permanent: 5...70 % |
| Air pressure [kPa] | 80...106 |
| Max. height above sea level [m] | 2000 |
| Ionizing radiation | not permissible |
| Salt spray | IEC 60068-2-52 |
| Protection | IP 65; IP 67; IP 69K; (with ifm socket duly screwed on) |
| UV radiation | DIN ISO 4892-1, DIN ISO 4892-2 |
| Chemical media | test according to ISO 16750-5; The following media were tested for 22 hours at 75 °C: Liebherr Hydraulik 37; Liebherr Hydraulik Gear ATF; Liebherr Hydraulik Plus Arctic; diesel; biodiesel; brake fluid; urea; The following media were tested for 22 hours at 25 °C: battery acid; cold cleaner; ammonia-based cleaner; The following media were tested for 2 hours at 25 °C: wheel rim cleaner |
| EMC | IEC 60947-5-2; IEC 60947-5-3; EN 60947-5-3; EN 61000-4-2 ESD: 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 20 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 61000-4-8: 30 A/m; EN 55011: class B |
| Shock resistance | IEC 60947-5-2 |
| Vibration resistance | IEC 60947-5-2 |
| Complies with the requirements | ISO 13849-1: 2015 Category 2, PL d; IEC 61508 SIL 2; IEC 62061 SIL 2 |
| MIssion time TM [h] | ≤ 87600 |
| Mission time TM (additional indication) | 10 years |
| PFH [1/h] | 1,0E-07 |
| Масса | 130 |
| Mounting | non-flush mountable |
| Thread designation | M18 x 1 |
| Материал | housing: stainless steel (1.4404 / 316L); sensing face: PBT; Protective cover: PPS GF40; LED window: PA; lock nuts: stainless steel (1.4404 / 316L) |
| Items supplied | lock nuts: 2 |
| Remarks | Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37K) 24x24x1 mm |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated; Moulded body: PPS GF40 |