GG714S

ifm electronic gmbh GG714S

Fail-safe inductive sensor, GIGA4008-2PS/SIL2/V4A/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): GG714S
  • Статус производства: Не определён

Категории:

Технические характеристики

Electrical designPNP
Output function2 x OSSD (A1 and A2)
Enable zone [mm]0...6.5
HousingThreaded type
Dimensions [mm]M18 x 1 / L = 71.5
Special featuregold-plated contacts
Type of operationcontinuous operation (maintenance-free)
Safety-related sub-functionsafe state when properly undamped
ApplicationIndustrial applications
Напряжение питания19.2...30 DC
Напряжение питания30
Current consumption [mA]< 30
Protection classIII
Reverse polarity protectionyes
Max. power-on delay time [ms]1000
Напряжение питания2.5; (30 mA)
Permanent current rating of switching output DC [mA]100
Output dataInterface type C class 1
Напряжение питанияcompatible with EN 61131-2 inputs type 1, 2
Short-circuit protectionyes
Overload protectionno
Max. capacitive load CL_max [nF]20
Safe switching-off distance s(ar) [mm]11
Время отклика1
Время отклика1
Время отклика20
Рабочая температура-40...70
Rate of temperature change [K/min]0.5
Max. relative air humidity [%]briefly: 5...95 %; permanent: 5...70 %
Air pressure [kPa]80...106
Max. height above sea level [m]2000
Ionizing radiationnot permissible
Salt sprayIEC 60068-2-52
ProtectionIP 65; IP 67; IP 69K; (with ifm socket duly screwed on)
UV radiationDIN ISO 4892-1, DIN ISO 4892-2
Chemical mediatest according to ISO 16750-5; The following media were tested for 22 hours at 75 °C: Liebherr Hydraulik 37; Liebherr Hydraulik Gear ATF; Liebherr Hydraulik Plus Arctic; diesel; biodiesel; brake fluid; urea; The following media were tested for 22 hours at 25 °C: battery acid; cold cleaner; ammonia-based cleaner; The following media were tested for 2 hours at 25 °C: wheel rim cleaner
EMCIEC 60947-5-2; IEC 60947-5-3; EN 60947-5-3; EN 61000-4-2 ESD: 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 20 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 61000-4-8: 30 A/m; EN 55011: class B
Shock resistanceIEC 60947-5-2
Vibration resistanceIEC 60947-5-2
Complies with the requirementsISO 13849-1: 2015 Category 2, PL d; IEC 61508 SIL 2; IEC 62061 SIL 2
MIssion time TM [h]≤ 87600
Mission time TM (additional indication)10 years
PFH [1/h]1,0E-07
Масса130
Mountingnon-flush mountable
Thread designationM18 x 1
Материалhousing: stainless steel (1.4404 / 316L); sensing face: PBT; Protective cover: PPS GF40; LED window: PA; lock nuts: stainless steel (1.4404 / 316L)
Items suppliedlock nuts: 2
RemarksUnless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37K) 24x24x1 mm
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated; Moulded body: PPS GF40
Получить предложение по этой позиции