ifm electronic gmbh GI761S
Fail-safe inductive sensor, GIIK4008B2PS/SIL2/AM/US
Категории:
Технические характеристики
| Electrical design | PNP |
|---|---|
| Output function | 2 x OSSD (A1 and A2) |
| Enable zone [mm] | 0...6 |
| Housing | Threaded type |
| Dimensions [mm] | M30 x 1.5 / L = 65 |
| Special feature | gold-plated contacts; Full-metal housing |
| Type of operation | permanent operation |
| Safety-related sub-function | safe state when properly undamped |
| Application | Use in mobile and harsh applications |
| Напряжение питания | 9...32 DC |
| Напряжение питания | 60 |
| Current consumption [mA] | < 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 500 |
| Напряжение питания | 2.5 |
| Number of OSSD outputs | 2 |
| Max. current load per OSSD output [mA] | 50 |
| Output data | Interface type C class 1 |
| Напряжение питания | compatible with EN 61131-2 inputs type 1, 2 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Max. capacitive load CL_max [nF] | 20 |
| Safe switch-off distance sAs (sar) [mm] | 18 |
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.8 / aluminum: 0.6 / copper: 0.3 |
| Время отклика | 20 |
| Время отклика | 20 |
| Risk time / error handling time (toff max) [ms] | 100; (at ambient temperature <-25 °C: 250 ms; flush mounting with a single stainless steel fixing nut: 250 ms) |
| Рабочая температура | -40...85 |
| Max. height above sea level [m] | 3000 |
| Ionizing radiation | not permissible |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
| EMC | industrial environments; EN 60947-5-3; EN 61000-4-2 ESD: 6 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 20 V/m 80...1000 MHz; EN 61000-4-3 HF radiated: 10 V/m 1,4...2,0 GHz / 3 V/m 2,0...6,0 GHz; EN 61000-4-4 Burst: 2 kV; EN 61000-4-5 Surge: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 61000-4-8: 30 A/m 50/60 Hz / 1000 A/m 0 Hz; EN 55011: class B; Mobile applications: only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems; ISO 10605 ESD: 8 kV CD / 15 kV AD; ISO 11452-2, ISO 11452-5 radiated immunity: 100 V/m 400...3000 MHz; ISO 7637-2, ISO 16750-2 conducted immunity: 12 V / 24 V; pulse: 1 2a 2b 3a 3b 4 5b; Severity level: III III III III III III 58V; Failure criterion: B A B A A C/B A/C; EN 55025: class 3 |
| Shock resistance | EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Ea: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature changes | EN 60068-2-14 Na: TA = -40°C; TB = 85°C; t1 = 45 min; t2 = 10 s 100 cycles |
| Vibration resistance | EN 60068-2-6 Fc: 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes; EN 60068-2-64 Fh: 5.9 g RMS / effective acceleration for chassis mounting; ISO 19014-3: 5.7 g RMS / effective acceleration |
| Salt spray test | EN 60068-2-52 Kb: severity level 5 (4 test cycles) |
| Complies with the requirements | ISO 13849-1 Category 2, PL d; IEC 61508 SIL 2, HFT 0, SC 2 |
| MIssion time TM [h] | ≤ 87600 |
| Mission time TM (additional indication) | industrial environments Temperature range -25...70 °C ≤ 175200 |
| PFH [1/h] | < 1,5E-07 |
| Масса | 134.1 |
| Mounting | flush mountable |
| Thread designation | M30 x 1.5 |
| Материал | threaded sleeve: stainless steel (1.4404 / 316L); sensing face: stainless steel (1.4404 / 316L); LED window: PEI; LED sealing: PU; lock nuts: stainless steel (1.4404 / 316L) |
| Tightening torque [Nm] | 70 |
| Full-metal housing | yes |
| Display | Display switching status: 4 LED, yellow |
| Items supplied | lock nuts: 2 |
| Remarks | meets the environmental and EMC requirements for operation in agricultural and forestry machinery, earthworks and construction machines as well as in industrial trucks; can be used in applications up to SIL 2 in accordance with IEC 62061, MPL d in accordance with ISO 19014-3 and Ag PL d in accordance with ISO 25119; Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.; (FE360 = ST37-2K) 30x30x1 mm; the correction factors apply to an ambient temperature of 20°C; do not use a correction factor for the safe switch-off distance sAs/(sar) |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |