ifm electronic gmbh IGM206
Inductive sensor, IGK3008BBPKG/M/60V/6M/ZH
Категории:
Технические характеристики
| Electrical design | PNP |
|---|---|
| Output function | normally open |
| Sensing range [mm] | 8 |
| Housing | Threaded type |
| Dimensions [mm] | M18 x 1 / L = 81 |
| Special feature | Increased sensing range |
| Application | Use in mobile and harsh applications |
| Напряжение питания | 10...60 DC |
| Current consumption [mA] | < 10 |
| Protection class | II |
| Reverse polarity protection | yes |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Switching frequency DC [Hz] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Operating distance [mm] | 0...6.48 |
| Increased sensing range | yes |
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.45 / copper: 0.35 |
| Hysteresis [% of Sr] | 1...20 |
| Рабочая температура | -40...85 |
| Protection | IP 67; IP 69K |
| EMC | Automotive area; Noise emission and noise interference: ECE R10: E1 type approval; noise immunity according to DIN ISO 11452-2: 100 V/m; conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump); pulse: 1 2a 2b 3a 3b 4 Load dump; Severity level: III III III III III III Test A; Failure criterion: C A C A A C C; EN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 10 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-5 Surge: 0,5 kV mains line to line; EN 61000-4-6 HF conducted: 10 V; EN 55011: class B |
| Vibration resistance | EN 60068-2-6 Fc: 20 g (10...3000 Hz) / -20...50 °C; 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
| Shock resistance | EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| Continuous shock resistance | EN 60068-2-27: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Fast temperature changes | EN 60068-2-14 Na: TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test | EN 60068-2-52 Kb: severity level 5 (4 test cycles) |
| MTTF [years] | 1110 |
| UL approval | Ta: 0...40 °C; Enclosure type: Type 1; File number UL: E174191 |
| Масса | 307.5 |
| Mounting | flush mountable |
| Thread designation | M18 x 1 |
| Материал | housing: stainless steel; sensing face: LCP; lock nuts: brass |
| Display | Switching status: 4 x 90° LED, yellow |
| Items supplied | lock nuts: 2 |
| Pack quantity | 1 pcs. |
| Cable | 6 m, PUR, Ø 5.4 mm; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |