IQ2009

ifm electronic gmbh IQ2009

Inductive sensor with IO-Link, IQ23007BFRKG/IO/0.3M/PUR/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): IQ2009
  • Статус производства: Не определён

Категории:

Технические характеристики

Electrical designPNP/NPN; (configurable)
Output functionnormally open / closed; (configurable)
Communication interfaceIO-Link
Housingrectangular
Dimensions [mm]20 x 8 x 32
ApplicationIndustrial applications; For use where space is restricted
Напряжение питания10...30 DC
Current consumption [mA]< 30
Protection classIII
Reverse polarity protectionyes
Напряжение питания2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]300
Short-circuit protectionyes
Overload protectionyes
Switch point IO-Link [mm]1.4...7; (configurable)
Measuring range IO-Link [mm]0.75...7.5
Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3
Hysteresis [% of Sr]3...15
Note on hysteresisconfigurable
Linearity error IO-Link [%]± 2; (of the final value of the measuring range)
Repeatability IO-Link [%]± 1; (of the final value of the measuring range)
Temperature coefficient [%/K vom MEW]± 0,6; (-25...70 °C: ± 0,3)
Temperature drift± 10 %; (of the final value of the measuring range)
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 0: Generic Profiled Sensor; Function: Multiple switching signal; Function: Teach channel; Common - I&D: Identification and Diagnosis
SIO modeyes
Required master port classA
Min. process cycle time [ms]3.2
IO-Link process data (cyclical)Function: bit length; process value: 16; device status: 4; binary switching information: 2
IO-Link functions (acyclical)application specific tag; operating hours counter
Supported DeviceIDsType of operation: DeviceID; default: 1106
NoteFor further information please see the IODD PDF file at "Downloads"
Рабочая температура-40...85
ProtectionIP 65; IP 66; IP 67; IP 68
EMCEN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 10 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; EN 55011: class B
Vibration resistanceEN 60068-2-6 Fc: 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistanceEN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistanceEN 60068-2-27: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changesEN 60068-2-14 Na: TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles
MTTF [years]787
Embedded software includedyes
UL approvalTa: -25...70 °C; Enclosure type: Type 1; voltage supply: Limited Voltage/Current; UL approval number: A016; File number UL: E174191
Масса42.7
Mountingflush mountable
Материалhousing: diecast zinc special coating; sensing face: PBT orange; LED window: TPU (urethane); potting: PUR
DisplayDisplay operation: 1 x LED, green; Switching status: 1 x LED, yellow
Pack quantity1 pcs.
Cable0.3 m, PUR, Ø 4.9 mm; 3 x 0.34 mm²
Connector1 x M12; coding: A; Contacts: 3
Получить предложение по этой позиции