ifm electronic gmbh KQ1001

Continuous level sensor, KQ-5xxxNFPKG/IO/0,1M/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): KQ1001
  • Статус производства: Не определён

Категории:

Технические характеристики

Electrical designPNP/NPN; (configurable)
Communication interfaceIO-Link
Housingrectangular
Dimensions [mm]255 x 28 x 16.7
ApplicationContinuous level measurement behind non-metallic and non-conductive surfaces
Mediadry bulk material; aqueous solutions; oils
Cannot be used forvery adhesive media
Напряжение питания10...30 DC; (IO-Link: 18...30 DC)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Max. power-on delay time [ms]1300
Measuring principlecapacitive
Number of inputs and outputsNumber of digital outputs: 3
Number of digital outputs3
Permanent current rating of switching output DC [mA]200
Max. resistance switching output [Ω]8
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring range [mm]< 200
Detection range [mm]228
Set point SP [%]5...95
Reset point rP [%]4...94
In steps of [%]1
Repeatability [% of the final value]2
Offset deviation [% of the final value]4
Resolution [% of the final value]1
Linearity deviation [% of the final value]1
Время отклика1300
Parameter setting optionsDamping; hysteresis / window; fault indication; Diagnostic function; Sensitivity; internal temperature; limitation of measuring range; adjustable switching delay; zero-point calibration; direction of installation; LEDs can be deactivated
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis
SIO modeyes
Required master port classA
Process data analog1
Process data binary3
Min. process cycle time [ms]7.2
IO-Link process data (cyclical)Function: bit length; process value: 16; exponent: 8; device status: 4; binary switching information: 3
IO-Link functions (acyclical)direction of installation; limitation of sensor elements; Sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED mode; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data level
Supported DeviceIDsType of operation: DeviceID; default: 924
NoteFor further information please see the IODD PDF file at "Downloads"
ApplicationsDIN EN 60654-1 application class B2
Рабочая температура-20...80
Storage temperature [°C]-25...85
ProtectionIP 65
EMCDIN EN 61000-6-4 30 - 230 MHz: 40 dBµV/m QP / 10 m distance; 230 - 1 GHz: 47 dBµV/m QP / 10 m distance; DIN EN 61000-4-2: ± 25 kV AD / ± 25 kV CD; DIN EN 61000-4-3: 80 MHz - / 1 GHz 10 V/m; DIN EN 61000-4-4: ± 2.5 kV / 5 kHz; ± 2.5 kV / 100 kHz; DIN EN 61000-4-6: 10 V
Shock resistanceEN 60068-2-27: 15 g 11 ms
Vibration resistanceEN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]290
UL approvalTa: -25...60 °C; Enclosure type: Type 1; voltage supply: Limited Voltage/Current; UL approval number: D006; File number UL: E174191
Масса377.5
Материалhousing: PBT; cover: PC
DisplayPower: 1 x LED, green; Switching status: 3 x LED, yellow; Function: 20 x LED, green
Items suppliedadhesive tape: 1 x (1,2 x 23 x 240 mm)
Accessories (optional)Mounting adapter: 2, E12675; Mounting adapter: 2, E12676; Fixing strap: 5, E10880; adhesive tape: 10, E12677
RemarksWhen used on IO-Link class B masters, switching outputs OUT2, OUT3 must be turned off
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 5