LDL101

ifm electronic gmbh LDL101

Conductive conductivity sensor, COND CONDUCTIVITY UPW HYG G1/2

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): LDL101
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of analog outputs: 1
Process connectionthreaded connection G 1/2 external thread sealing cone optional:hygienic PEEK gasket according to EHEDG
Special featuregold-plated contacts
MediaConductive liquids
Note on mediaultra-pure water
Cannot be used forSee the operating instructions, chapter "Function and features".
Medium temperature [°C]-25...100; (< 1 h: 150)
Pressure rating35 bar: 3.5 MPa
Vacuum resistance-1000 mbar: -0.1 MPa
Напряжение питания18...30 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Measuring principlekonduktiv
Total number of outputs1
Output signalanalog signal; IO-Link
Output functionanalog output scalable; selectable conductivity / temperature
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω]500
Measuring range [µS/cm]0.04...1000
Resolution [µS/cm]0...9,999: 0.001; 10...99,99: 0.01; 100...1000: 0.1
Measuring range [°C]-25...150
Accuracy (in the measuring range)3 % MW ± 0,03 µS/cm
Drift [%/K]0,1 %/K MW
Repeatability1 % MW ± 0,010 µS/cm
Long-term stability1,5 % MW ± 0,015 µS/cm
Accuracy [K]20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K
Repeatability [K]0,2
Resolution [K]0.1
Время отклика< 9; (T09)
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis
SIO modeno
Required master port classA
Process data analog1
Min. process cycle time [ms]6.4
Supported DeviceIDsType of operation: DeviceID; default: 1455
Рабочая температура-40...60
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68)
EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27: 50 g (11 ms)
Vibration resistanceDIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]173
UL approvalFile number UL: E364788
Масса346.8
Материалstainless steel (1.4404 / 316L); PEI; FKM
Материалstainless steel (1.4435 / 316L); PEEK
Surface characteristics Ra/Rz of the wetted partsRa ≤ 0.8 µm
RemarksMW = Measured value
NotesDigital meets analog: integrating modern IO-Link sensors the analog way. The EIO104 allows you to realize two analog signals from intelligent IO-Link sensors with several process values.
Pack quantity1 pcs.
Connector1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции