Технические характеристики
| Number of inputs and outputs | Number of analog outputs: 1 |
|---|---|
| Process connection | G 1 external thread Aseptoflex Vario |
| Special feature | gold-plated contacts |
| Media | Conductive liquids |
| Note on media | water; milk; CIP liquids |
| Cannot be used for | See the operating instructions, chapter "Function and features". |
| Medium temperature [°C] | -25...100; (< 1 h: 150) |
| Pressure rating | 16 bar: 1.6 MPa |
| Vacuum resistance [mbar] | -1000 |
| MAWP (for applications according to CRN) | 12 bar: 1.2 MPa |
| Напряжение питания | 18...30 DC |
| Current consumption [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 2 |
| Measuring principle | inductive |
| Total number of outputs | 1 |
| Output signal | analog signal; IO-Link |
| Output function | analog output scalable; selectable conductivity / temperature |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Measuring range [µS/cm] | 100...1000000 |
| Resolution [µS/cm] | 0...10.000: 1; 10.000...100.000: 10; 100.000...1.000.000: 100 |
| Measuring range [°C] | -25...150 |
| Accuracy (in the measuring range) | 2 % MW ± 25 µS/cm |
| Drift [%/K] | 0,1 %/K MW |
| Repeatability | 1 % MW ± 25 µS/cm |
| Long-term stability | 0,5 % MW ± 25 µS/cm |
| Accuracy [K] | 20...50 °C: < ± 0,2 K; -25...150 °C: < ± 1,5 K |
| Repeatability [K] | 0,2 |
| Resolution [K] | 0.1 |
| Время отклика | < 25; (T09) |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis |
| SIO mode | no |
| Required master port class | A |
| Process data analog | 1 |
| Min. process cycle time [ms] | 6.4 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 922 |
| Рабочая температура | -40...60 |
| Storage temperature [°C] | -40...85 |
| Protection | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68) |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 20 g (10...2000 Hz) |
| MTTF [years] | 129 |
| UL approval | File number UL: E364788 |
| Масса | 692.6 |
| Материал | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
| Материал | PEEK |
| Surface characteristics Ra/Rz of the wetted parts | Ra ≤ 0.8 µm |
| Remarks | MW = Measured value |
| Notes | Digital meets analog: integrating modern IO-Link sensors the analog way. The EIO104 allows you to realize two analog signals from intelligent IO-Link sensors with several process values. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated |