ifm electronic gmbh LMH610
Sensor for point level detection, LMACE-A12K-QSKG-1/US
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Factory setting | oils; oil-based media |
| Process connection | threaded connection G 1/2 |
| Special feature | gold-plated contacts |
| Media | Fluessige_Medien pastoese_Medien; powder |
| Conditionally suitable for | use at pressures > 40…100 bar only on request |
| Cannot be used for | See the operating instructions, chapter "Function and features". |
| Medium temperature [°C] | when used under hygienic conditions with accessories: E43030: -15...240; when used under hygienic conditions with accessories: E43033: -15...200; when used under hygienic conditions with accessories: E43031: -20...150; when used under industrial conditions with accessories: E43032: -20...250 |
| Pressure rating [bar] | 40 |
| Vacuum resistance [mbar] | -1000 |
| Probe length [mm] | 13.7 |
| Напряжение питания | 18...30 DC |
| Current consumption [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
| Measuring principle | capacitive |
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Measuring range [°C] | -40...250 |
| Resolution [°C] | 0.1 |
| Accuracy [K] | ± 0,6 |
| Temperature drift per 10 K [K] | ± 0.055 |
| Время отклика | < 0.5 |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 4.1.2: Measuring and Switching Sensor, 2 channel; Common - I&D: Identification and Diagnosis; Extension: Quantity detection, switches when value exceeds the setpoint; Function: Locator; Function: ProductURI |
| SIO mode | yes |
| Required master port class | A |
| Min. process cycle time [ms] | 4.5 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1516 |
| Рабочая температура | -40...85 |
| Рабочая температура | Medium temperature: ≤ 200 °C; -40...60 °C; Medium temperature: ≤ 250 °C |
| Storage temperature [°C] | -40...85 |
| Protection | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP68) |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-4: : in plastic or open metal tanks; DIN EN 61000-6-3: : in a closed metal tank |
| Shock resistance | DIN EN 60068-2-27: 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 20 g (10...2000 Hz) |
| MTTF [years] | 356 |
| UL approval | UL approval number: H017; File number UL: E174191 |
| Масса | 301.7 |
| Housing | tubular |
| Dimensions [mm] | Ø 30 / L = 169 |
| Материал | housing: stainless steel (1.4404 / 316L); Male receptacle: PEI; O-ring: FKM |
| Материал | probe: ceramics (99.97 % Al2O3) surface characteristics: Ra < 0,38 µm / Rz = 4 µm; O-ring (internal): FFKM |
| Display | Switching status: LED, yellow; operating status: LED, green; warning: LED, red |
| Accessory required | sealing set, E43030; sealing set, E43033; sealing set, E43031; Gasket, E43032 |
| Remarks | An overview of the materials, approvals and conformities of the accessories can be found in the respective data sheet.; The E43031 sealing kit slightly increases the sensor sensitivity; the values for accuracy and response times apply to flowing water and an isolated process; see operating instructions |
| Notes | To ensure secure mounting compatible with the medium, a sealing set suitable for the application must be used. Please refer to chapters Medium temperature and Accessories.; These sealing sets are not included. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |