LW2720

ifm electronic gmbh LW2720

Continuous level sensor, NON-CONTACT LEVEL TRANSMITTER

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): LW2720
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 1; Number of analog outputs: 1
Process connectionG 1 Aseptoflex Vario
Special featuregold-plated contacts
Dielectric constant of the medium≥ 2
Recommended mediawater; water-based media
Medium temperature [°C]-40...150; (see diagram:)
Maximum speed of the change of level [mm/s]200
Pressure rating [bar]8
Note on pressure rating0 bar at medium temperature < - 20 C
Vacuum resistance [mbar]-1000
MAWP (for applications according to CRN) [bar]8
Radio approval forEU/RED; Great Britain; South Korea; USA; Canada; Australia; New Zealand; Vietnam; Singapore; Argentina; Brazil; Japan; Taiwan; South Africa; Mexico
Note on radio approvalThe list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”.
Напряжение питания18...30 DC
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]< 15
Measuring principleFMCW (80 GHz technology); frequency range 77 - 81 GHz
Total number of outputs2
Output signalswitching signal; analog signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs1; (2 configurable)
Output functionnormally open / closed; (configurable)
Напряжение питания2.5
Permanent current rating of switching output DC [mA]50
Number of analog outputs1
Analog current output [mA]4...20, invertible; (scalable)
Max. load [Ω]43,5 * (Ub – 18) + 600 Ω
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring range [m]10; (see diagram:)
Sampling rate [Hz]> 3
Accuracy± 2 mm
Resolution [mm]1
Zero signal (current) [mA]3.8
Full signal (current) [mA]20.5
Temperature drift per 10 K± 1 mm
Время отклика330
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 3.1: Measuring Sensor; Common - I&D: Identification and Diagnosis; Function: Multiple switching signal
SIO modeyes
Required master port classA
Process data analog1
Process data binary2
Min. process cycle time [ms]6
Supported DeviceIDsType of operation: DeviceID; default: 1324
Рабочая температура-40...80
Рабочая температураsee diagram:
Storage temperature [°C]-40...90
ProtectionIP 68; IP 69K
EMCDIN EN 61326-1: group 1: Class A (IO-Link active); B (IO-Link not active, with analog and switching outputs)
Shock resistanceDIN EN 60068-2-27: 50 g (11 ms) / 20 g (6 ms)
Vibration resistanceIEC 61298-3: 2 g (10...1000 Hz)
MTTF [years]330
Масса727.15
Материалstainless steel (1.4404 / 316L); PA; FKM; FVMQ
МатериалPTFE; EPDM
Surface characteristics Ra/Rz of the wetted partsRa < 0.76 µm
NotesAn IO-Link master and a parameter setting software (e.g. moneo or LR DEVICE) are required for initial set-up.
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции