PA6229

ifm electronic gmbh PA6229

Pressure transmitter with ceramic measuring cell, PA-0-1-RBN14-A-ZVG/US/ /V

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): PA6229
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of analog outputs: 1
Measuring range-1...0 bar: -1000...0 mbar: -14.5...0 psi: -100...0 kPa
Process connectionthreaded connection 1/4" NPT Internal thread
Special featuregold-plated contacts
Applicationfor industrial applications
Medialiquids and gases
Medium temperature [°C]-25...90; (on request: -40...90 °C)
Min. burst pressure30 bar: 435 psi: 3 MPa
Pressure rating10 bar: 145 psi: 1 MPa
Type of pressurerelative pressure; vacuum
Напряжение питания9.6...32 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Total number of outputs1
Output signalanalog signal
Number of analog outputs1
Analog current output [mA]20...4
Max. load [Ω]720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA)
Overload protectionyes
Repeatability [% of the span]< 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]0,1; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]0,2; (0...80 °C)
Время отклика3
Рабочая температура-25...80
Storage temperature [°C]-40...100
ProtectionIP 65
EMCEN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 30 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; radiation of interference: according to the automotive directive 2004/104/EC / CISPR 25; noise immunity: according to the automotive directive 2004/104/EC / ISO 11452-2; HF radiated: 100 V/m; pulse resistance: ISO 7637-2 / severity level 3
Shock resistanceDIN IEC 68-2-27: 50 g (11 ms)
Vibration resistanceDIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]506
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса221.5
Housingtubular
Dimensions [mm]Ø 30 / L = 75
Материалstainless steel (1.4404 / 316L); FKM; PA; EPDM/X
Материалstainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles100 million
Restrictor element integratedno (can be retrofitted)
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции