ifm electronic gmbh PI1804
Flush pressure sensor with display, PI-010-REA01-MFRKG/US/ /P
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|---|
| Measuring range | -25...150 °C: -13...302 °F |
| Process connection | threaded connection G 1 external thread sealing cone - 27 mm; Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
| Special feature | gold-plated contacts |
| Application | flush mountable for the food and beverage industry |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] | -25...150 |
| Min. burst pressure | 150 bar: 2175 psi: 15 MPa |
| Pressure rating | 50 bar: 725 psi: 5 MPa |
| Vacuum resistance | -1000 mbar: -0.1 MPa |
| Type of pressure | relative pressure; vacuum |
| No dead space | yes |
| MAWP (for applications according to CRN) [bar] | 50 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Integrated watchdog | yes |
| Напряжение питания | 18...30 DC |
| Current consumption [mA] | 5...45; (430 bei max. Laststrom) |
| Power-on delay time [s] | < 0.5 |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20, invertible; (scalable) |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Max. load [Ω] | (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V) |
| Напряжение питания | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 125 |
| Set point SP | -0.99...10 bar: -14.3...145 psi: -0.099...1 MPa |
| Reset point rP | -1...9.99 bar: -14.5...144.8 psi: -0.1...0.999 MPa |
| Analog start point | -1...8 bar: -14.5...116 psi: -0.1...0.8 MPa |
| Analog end point | 1...10 bar: 14.5...145 psi: 0.1...1 MPa |
| Min. difference between SP and rP | 0.02 bar: 0.3 psi: 0.002 MPa |
| In steps of | 0.01 bar: 0.1 psi: 0.001 MPa |
| Factory setting | SP1 = 2.50 bar: rP1 = 2.30 bar; SP2 = 7.50 bar: rP2 = 7.30 bar; ASP = 0.00 bar: AEP = 10.00 bar; dAP = 0.06 s: dAA = 0.06 s |
| Switch point accuracy [% of the span] | < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1) |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] | < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
| Zero-point stabilization [% of the span] | IO-Link, analog output: 0,15; (see operating instructions zero-point behavior); Display, Switching output: 0,2 |
| Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Total deviation over temperature range | Temperature range: total deviation; -25...15 °C: Characteristics deviation ± 0,05 % of the span / 10 K; 15...80 °C: Characteristics deviation; 80...150 °C: Characteristics deviation ± 0,1 % of the span / 10 K |
| Notes on the accuracy / deviation | for further details see section Diagrams and graphs |
| Accuracy [K] | ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur )) |
| Repeatability [K] | ± 0,2 |
| Resolution [K] | 0.2 |
| Damping process value dAP [s] | 0...99.99 |
| Damping for the analog output dAA [s] | 0...99.99 |
| Время отклика | 7 |
| Время отклика | 3 |
| Dynamic response T05 / T09 [s] | < 45 / < 200; (DIN EN 60751 water ; > 0,9 m/s) |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D: Identification and Diagnosis; Function: Measurement data, high resolution |
| SIO mode | yes |
| Required master port class | A |
| Min. process cycle time [ms] | 5.6 |
| IO-Link resolution pressure [bar] | 0.0005 |
| IO-Link resolution temperature [K] | 0.2 |
| IO-Link process data (cyclical) | Function: bit length; pressure: 32; temperature: 32; device status: 4; binary switching information: 2 |
| IO-Link functions (acyclical) | application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; measuring cell diagnosis |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1156 |
| Рабочая температура | -25...80 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 67; IP 68; IP 69K |
| EMC | DIN EN 61326-1 |
| Shock resistance | DIN EN 60068-2-27: 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 20 g (10...2000 Hz) |
| MTTF [years] | 214 |
| UL approval | UL approval number: J049; File number UL: E174189 |
| Масса | 385.2 |
| Housing | tubular |
| Dimensions [mm] | Ø 50 / L = 106 |
| Материал | Housing: stainless steel (1.4404 / 316L); Pushbuttons: PBT; sealings: FKM; M12 connector: PEI; Display: PFA; ventilation diaphragm: PTFE |
| Материал | measuring cell: ceramics (99.9 % Al2O3); Process connection: stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; sealing: PTFE |
| Min. pressure cycles | 100 million |
| Tightening torque [Nm] | 20 |
| Display | Display unit: LED, green; Switching status: LED, yellow; Function display: alphanumeric display, 4-digit; Measured values: alphanumeric display, 4-digit |
| Display unit | bar; psi; MPa |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |