ifm electronic gmbh PP7551
Pressure switch with ceramic measuring cell, PP-250-SBG14-QFPKG/US/ /V
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|---|
| Measuring range | 0...250 bar: 0...3625 psi: 0...25 MPa |
| Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
| Application | for mobile applications; for industrial applications; for railway applications |
| Media | liquids and gases |
| Conditionally suitable for | use in gases at pressures > 25 bar only on request |
| Medium temperature [°C] | -25...90 |
| Min. burst pressure | 850 bar: 12300 psi: 85 MPa |
| Pressure rating | 400 bar: 5800 psi: 40 MPa |
| Type of pressure | relative pressure |
| Напряжение питания | 9.6...36 DC; (communication mode: 18...32) |
| Current consumption [mA] | < 45 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.3 |
| Total number of outputs | 2 |
| Output signal | switching signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Set point SP | 2...250 bar: 40...3620 psi: 0.2...25 MPa |
| Reset point rP | 1...249 bar: 20...3600 psi: 0.1...24.9 MPa |
| In steps of | 1 bar: 20 psi: 0.1 MPa |
| Factory setting | SP1 = 63 bar: rP1 = 58 bar; SP2 = 188 bar: rP2 = 183 bar; OUT1 = Hno: OUT2 = Hno |
| Switch point accuracy [% of the span] | < ± 0,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Zero-point stabilization [% of the span] | IO-Link: 1,0; (see operating instructions zero-point behavior) |
| Hysteresis deviation [% of the span] | < ± 0,1 |
| Long-term stability [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
| Время отклика | < 3 |
| Damping process value dAP in steps [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.0 |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 1 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 2.3 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 3 |
| Рабочая температура | -25...85 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
| EMC | noise immunity: EN 61000-6-2; EN 61000-4-2 ESD: 4 kV contact discharge / 15 kV air discharge; EN 61000-4-3 HF radiated: 20 V/m; EN 61000-4-4 Burst: 4 kV coupling clamp; EN 61000-4-5 Surge: 0,5 kV supply / 1 kV signal for DC units; EN 61000-4-6 HF conducted: 10 V; noise immunity: according to the automotive directive 1995/54/EC / 04/104EG / 05/83/EG; Absorber chamber test to ISO 11452-2:: 80 V/m |
| Shock resistance | DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g; DIN EN 61373: Category 3 |
| Vibration resistance | DIN IEC 68-2-6: 20 g (10...2000 Hz); DIN EN 60068-2-64: 14 g; DIN EN 61373: Category 2 |
| MTTF [years] | 308 |
| UL approval | UL approval number: J010 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications | DIN EN 50155: Klasse T3, C1, S1 |
| Масса | 227.5 |
| Housing | tubular |
| Dimensions [mm] | Ø 30 / L = 79.5 |
| Материал | stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
| Материал | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Restrictor element integrated | no (can be retrofitted) |
| Display | Power: 2 x LED, green; Switching status: 2 x LED, yellow |
| Teach function | yes |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4 |