ifm electronic gmbh R1D200
radar distance sensor, R1DBAF6KG/US/IO-Link
Категории:
Технические характеристики
| Communication interface | IO-Link |
|---|---|
| Housing | rectangular |
| Dimensions [mm] | 80 x 80 x 45 |
| Electrical design | PNP/NPN; (configurable) |
| Output function | normally open / closed; (configurable) |
| Radio approval for | EU/RED; Great Britain; Australia; Japan; Mexico; Namibia; New Zealand; South Africa; Hong Kong; USA; Canada; Chile; Brazil; Ecuador; Cameroon; Panama; Morocco; Mongolia; Malaysia; Paraguay; Ukraine |
| Note on radio approval | The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”. |
| Напряжение питания | 10...30 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4) |
| Current consumption [mA] | < 300; (mean value: 150 mA) |
| Power consumption [W] | 21; (maximum) |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 1000 |
| Operating frequency [GHz] | 77...81 |
| Maximum radiated average power spectral density EIRP [dBm/MHz] | -17 |
| Radiated peak power EIRP [dBm] | 30 |
| Total number of inputs and outputs | 3 |
| Inputs | IN1: activation/deactivation of the radar |
| Total number of outputs | 2 |
| Output signal | OUT1: switching signal; IO-Link; OUT2: switching signal; analog signal |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Analog current output [mA] | 4...20, invertible; (scalable) |
| Max. load [Ω] | 500; (< 250 Ω: Ub 16...30 V DC; 250...500 Ω: Ub 18...30 V DC) |
| Напряжение питания | 0...10, invertible; (scalable) |
| Min. load [Ω] | 2000 |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 200 |
| Range [m] | 0.1...50; (referred to a 10 cm corner reflector) |
| Angle of aperture cylindrical [°] | Horizontal: 40; vertical: 20 |
| Measuring range [m] | 0.1...50; (see diagram:) |
| Sampling rate [Hz] | 20...100 |
| Hysteresis [mm] | 5; (configurable) |
| Temperature coefficient analog output [% of the span / 10 K] | ± 0,1 |
| Repeatability analog output [% of the span] | < 0,1 |
| Linearity error of analog output [% of the span] | ± 0,15 |
| Precision analog output [% of the span] | ± 0,2 (in addition to the accuracy specifications in the further data section) |
| Parameter setting options | only via IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Function: Locator; Function: ProductURI |
| SIO mode | yes |
| Required master port class | A |
| Min. process cycle time [ms] | 3.2 |
| IO-Link process data (cyclical) | Function: bit length; Distance: 32; speed: 32; Power: 8; RCS: 8; sensor inclination: 1; device status: 4; binary switching information: 4 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter; number of trigger events; internal temperature; ROI setting |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1518 |
| Рабочая температура | -40...80 |
| Рабочая температура | without using the analog output: -40...85 °C |
| Storage temperature [°C] | -40...85 |
| Protection | IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps) |
| EMC | DIN EN 61000-4-2 ESD: 4 kV CD / 8 kV AD; DIN EN 61000-4-3 HF radiated: 10 V/m; DIN EN 61000-4-4 Burst: 2 kV; DIN EN 61000-4-6 HF conducted: 10 V; DIN EN 61000-6-2: noise immunity / industrial environments; EN 55032 emission: class A |
| Impact resistance | IEC 62262: IK06 (1J) |
| Vibration resistance | DIN EN 60068-2-6 Fc: 10 g 10 frequency cycles, 1 octave/minute, in 3 axes |
| Shock resistance | DIN EN 60068-2-27 Ea: 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes |
| Continuous shock resistance | DIN EN 60068-2-29 Eb: 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes |
| Fast temperature changes | DIN EN 60068-2-14 Na: TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles |
| Salt spray test | DIN EN 60068-2-11 Ka: 8 test cycles |
| Electrical safety | DIN EN 61010-2-201: electric shock / electrical supply only via SELV/PELV circuits |
| MTTF [years] | 53 |
| UL approval | Ta: -40...65 °C; File number UL: E205959 |
| Масса | 412.15 |
| Mounting | flush mountable |
| Материал | housing: PA; radome: PEI; sealing: HNBR |
| Display | Switching status: 2x LED, yellow; Power: 1x LED, green; errors: 1x LED, red |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 5 |