ifm electronic gmbh SB4256
Flow meter with fast response and display, SBG32KM0FRKG
Категории:
Технические характеристики
| Measuring range | -10...100 °C: 14...212 °F |
|---|---|
| Process connection | threaded connection G 1 1/2 Internal thread |
| Special feature | gold-plated contacts |
| Media | Liquids; oil (viscosity 100 mm²/s at 40° C) |
| Medium temperature [°C] | -10...100 |
| Pressure rating | 63 bar: 6.3 MPa |
| Note on pressure rating | at medium temperature >70°C: 50 bar / 5 MPa |
| Напряжение питания | 18...30 DC; (to SELV/PELV ; cULus - Class 2 source required) |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; frequency signal; IO-Link |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2 |
| Max. current load per output [mA] | 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature) |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output [Hz] | 0...10000 |
| Display range | -32...122 °C: -25.6...251.6 °F |
| Resolution | 0.1 °C: 0.1 °F |
| Set point SP | -9.3...100 °C: 15.2...212 °F |
| Reset point rP | -10...99.3 °C: 14...210.8 °F |
| Frequency end point, FEP | 12...100 °C: 53.6...212 °F |
| In steps of | 0.1 °C: 0.2 °F |
| Frequency at the end point FRP [Hz] | 10...10000 |
| In steps of [Hz] | 10 |
| Measuring dynamics | 1:50 |
| Frequency start point, FSP | -10...78 °C: 14...172.4 °F |
| Accuracy (in the measuring range) | ± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature) |
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,029 °C / K |
| Accuracy [K] | 3 K (25°C; Q > 1 l/min) |
| Время отклика | 0.01 |
| Damping process value dAP [s] | 0...5 |
| In steps of [s] | 0.1 |
| Damping for the analog output dAA [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) |
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; current/frequency output; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color; calibration factor |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 3.2 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1046 |
| Рабочая температура | 0...60 |
| Рабочая температура | medium temperature < 80 °C; medium temperature < 100 °C: 0...40 °C |
| Storage temperature [°C] | -15...80 |
| Protection | IP 65; IP 67 |
| EMC | EN IEC 61326-1 |
| Shock resistance | DIN EN 60068-2-27: 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| UL approval | UL approval number: I007; File number UL: E174189 |
| Pressure equipment directive | sound engineering practice |
| Масса | 2766.3 |
| Материал | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Материал | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Switching cycles mechanical | 10 million |
| Display | Display unit: 6 x LED, green; Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green alternating indication 4-digit; Programming: alphanumeric display, 4-digit |
| Remarks | Use of 200 micron filtration is recommended.; All data refer to oil with the following nominal viscosity: 100 mm²/s, 40 °C; MW = Measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |