SBN232

ifm electronic gmbh SBN232

Flow meter with fast response and display, SBN34IQ0FRKG

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SBN232
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range5...240 gph: 0.1...4 gpm
Process connectionthreaded connection 3/4" NPT Internal thread
Special featuregold-plated contacts
Applicationfor industrial applications
MediaLiquids; water; glycol solutions; Coolants; Öle (Viskosität 10 mm²/s bei 104 °F); Öle (Viskosität 46 mm²/s bei 104 °F)
Note on mediaoil 1 with viscosity: 10 mm²/s (104 °F); oil 2 with viscosity: 46 mm²/s (104 °F)
Medium temperature [°F]14...212
Pressure rating40 bar: 4 MPa
MAWP (for applications according to CRN) [bar]40
Напряжение питания18...30 DC; (to SELV/PELV)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]< 3
Total number of outputs2
Output signalswitching signal; analog signal; frequency signal; IO-Link; (configurable)
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical)10 million
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω]500
Short-circuit protectionyes
Overload protectionyes
Frequency of the output [Hz]0...10000
Display range0...288 gph: 0...4.8 gpm
Resolution1 gph: 0.05 gpm
Set point SP2...240 gph: 0.05...4 gpm
Reset point rP0...238 gph: 0...3.95 gpm
Frequency end point, FEP16...240 gph: 0.25...4 gpm
In steps of1 gph: 0.05 gpm
Frequency at the end point FRP [Hz]10...10000
Measuring dynamics1:50
Measuring range [°F]14...212
Display range [°F]-26...252
Resolution [°F]2
Set point SP [°F]16...212
Reset point rP [°F]14...210
In steps of [°F]2
Frequency start point, FSP [°F]14...172
Frequency end point, FEP [°F]54...212
Accuracy (in the measuring range)± (4 % MW + 1 % MEW); (Q > 0,3 l/min; medium and operating temperature: +71,6 °F ± 4K)
Repeatability± 1 % MEW
Temperature drift0,9802 °F / K
Accuracy [K]3 K (77 °F; Q > 1 l/min)
Время отклика0.01
Damping process value dAP [s]0...5
Damping for the analog output dAA [s]0...5
Dynamic response T05 / T09 [s]T09 = 120 (Q > 1 l/min)
Parameter setting optionshysteresis / window; normally open / closed; switching logic; current output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO modeyes
Required master port classA
Process data analog2
Process data binary2
Min. process cycle time [ms]3.2
Supported DeviceIDsType of operation: DeviceID; default: 565
Рабочая температура32...140
Рабочая температураmedium temperature < 176 °F; medium temperature < 212 °F: 32...104 °F
Storage temperature [°F]5...176
ProtectionIP 65; IP 67
EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27: 20 g (11 ms)
Vibration resistanceDIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]145
UL approvalUL approval number: I005; File number UL: E174189
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса696
Материалstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Материалstainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
DisplayDisplay unit: 3 x LED, green; Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green 4-digit; Programming: alphanumeric display, 4-digit
RemarksUse of 200 micron filtration is recommended.; All data refer to water (68 °F).; MW = Measured value; MEW = Final value of the measuring range
NotesPlease note the changed housing design!
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции