ifm electronic gmbh SBN246
Flow meter with fast response and display, SBN11IF0FRKG
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|---|
| Measuring range [gph] | 30...1620 |
| Process connection | threaded connection 1" NPT Internal thread |
| Special feature | gold-plated contacts |
| Application | for industrial applications |
| Media | Liquids; water; glycol solutions; Coolants; Öle (Viskosität 10 mm²/s bei 104 °F); Öle (Viskosität 46 mm²/s bei 104 °F) |
| Note on media | oil 1 with viscosity: 10 mm²/s (104 °F); oil 2 with viscosity: 46 mm²/s (104 °F) |
| Medium temperature [°F] | 14...212 |
| Pressure rating | 25 bar: 2.5 MPa |
| MAWP (for applications according to CRN) [bar] | 25 |
| Напряжение питания | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; frequency signal; IO-Link; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2 |
| Permanent current rating of switching output DC [mA] | 150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F)) |
| Switching cycles (mechanical) | 10 million |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Frequency of the output [Hz] | 0...10000 |
| Display range | 0...1940 gph: 0...32.4 gpm |
| Resolution | 10 gph: 0.1 gpm |
| Set point SP | 10...1620 gph: 0.2...27 gpm |
| Reset point rP | 0...1610 gph: 0...26.8 gpm |
| Frequency end point, FEP | 110...1620 gph: 1.8...27 gpm |
| In steps of | 10 gph: 0.1 gpm |
| Frequency at the end point FRP [Hz] | 10...10000 |
| Measuring dynamics | 1:50 |
| Measuring range [°F] | 14...212 |
| Display range [°F] | -26...252 |
| Resolution [°F] | 2 |
| Set point SP [°F] | 16...212 |
| Reset point rP [°F] | 14...210 |
| In steps of [°F] | 2 |
| Frequency start point, FSP [°F] | 14...172 |
| Frequency end point, FEP [°F] | 54...212 |
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 2 l/min; medium and operating temperature: +71,6 °F ± 4K) |
| Repeatability | ± 1 % MEW |
| Temperature drift | 0,9802 °F / K |
| Accuracy [K] | 3 K (77 °F; Q > 1 l/min) |
| Время отклика | 0.01 |
| Damping process value dAP [s] | 0...5 |
| Damping for the analog output dAA [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) |
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; current output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 2 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 3.2 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 568 |
| Рабочая температура | 32...140 |
| Рабочая температура | medium temperature < 176 °F; medium temperature < 212 °F: 32...104 °F |
| Storage temperature [°F] | 5...176 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 145 |
| UL approval | UL approval number: I006; File number UL: E174189 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Масса | 1292.4 |
| Материал | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Материал | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Display | Display unit: 3 x LED, green; Switching status: 2 x LED, yellow; Measured values: alphanumeric display, red/green 4-digit; Programming: alphanumeric display, 4-digit |
| Remarks | Use of 200 micron filtration is recommended.; All data refer to water (68 °F).; MW = Measured value; MEW = Final value of the measuring range |
| Notes | Please note the changed housing design! |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |